mutable-instruments/branches

Mutable Instruments Branches Probability / Bernoulli Gate

6 HP probability / bernoulli gate by Mutable Instruments: 4 inputs, 4 outputs, 4 controls, 3 modes.

Mutable Instruments · Branches Manual (full) ↗

Probability / Bernoulli Gate

Inputs 4

Inputs
JackWhat it doesRangeConnections
IN 1 914trigger input
trigger, gate
threshold 0.6 V
impedance 100000 Ω
→ Bernoulli gate 1
Probability CV 1 914probability CV
cv
-5 to 5 V, bipolar
impedance 100000 Ω
→ Bernoulli gate 1, Probability 1
IN 2 914trigger input
trigger, gate
threshold 0.6 V
impedance 100000 Ω
normalled from IN 1
→ Bernoulli gate 2
Probability CV 2 914probability CV
cv
-5 to 5 V, bipolar
impedance 100000 Ω
→ Bernoulli gate 2, Probability 2

The documents don't state: voltage, polarity (IN 1, IN 2); scaling, coupling, audio rate (all inputs).

Outputs 4

Outputs
JackWhat it doesRangeConnections
Output A 1 914heads output
trigger, gate
≤ 5 V
from Bernoulli gate 1
In 2 modes
  • Toggle mode: same/opposite output decision
  • Latch mode: held +5V until other
Output B 1 914tails output
trigger, gate
≤ 5 V
from Bernoulli gate 1
In 2 modes
  • Toggle mode: same/opposite output decision
  • Latch mode: held +5V until other
Output A 2 914heads output
trigger, gate
≤ 5 V
from Bernoulli gate 2
In 2 modes
  • Toggle mode: same/opposite output decision
  • Latch mode: held +5V until other
Output B 2 914tails output
trigger, gate
≤ 5 V
from Bernoulli gate 2
In 2 modes
  • Toggle mode: same/opposite output decision
  • Latch mode: held +5V until other

The documents don't state: polarity, pulse, coupling, impedance (all outputs).

Controls 4

Controls
ControlWhat it doesAffectsPositions
Probability 1 914heads/tails odds
knob
Bernoulli gate 1, Output A 1, Output B 1
  • extreme settings: non-random switch
  • maximum, toggle mode: alternates A and B
Mode button 1 914toggle/latch mode
button
Bernoulli gate 1
  • press: toggle mode on/off
  • hold >1s: latch mode on/off
Probability 2 914heads/tails odds
knob
Bernoulli gate 2, Output A 2, Output B 2
  • extreme settings: non-random switch
  • maximum, toggle mode: alternates A and B
Mode button 2 914toggle/latch mode
button
Bernoulli gate 2
  • press: toggle mode on/off
  • hold >1s: latch mode on/off

Blocks 2

Blocks and their connections
BlockKindTypesInputsControlsOutputsSource
Bernoulli gate 1Bernoulli gateGate / trigger processorIN 1, Probability CV 1Probability 1, Mode button 1Output A 1, Output B 1914
Bernoulli gate 2Bernoulli gateGate / trigger processorIN 2, Probability CV 2Probability 2, Mode button 2Output A 2, Output B 2914

Modes 3

Modes
ModeKindSelected bySelection methodSource
Coin tossrouting—default914
Toggle moderoutingMode button = presspress switch (B)914
Latch modeoutputMode button = hold >1shold switch (B) >1s914

Hidden functions 1

Hidden functions
FunctionTriggerAffectsSource
Latch modehold switch >1sOutput A, Output B914

Specs 10

Specs
SubjectQuantityValueConditionSource
gate inputsthreshold0.6 V—915
CV inputsrange-5 to 5 V—915
outputshigh level5 V—915
moduleresponse time15 µs—915
Mode buttonlatch hold time1 s—914
modulewidth6 HP—915
moduledepth25 mm—915
module+12V current10 mA—915
module-12V current1 mA—915
processorclock8 MHz—915

Properties 3

Properties
SubjectPropertyValueSource
modulesectionstwo identical914
processormodelATMega88p915
Toggle/Latch settingspersistencekept at power-off914

Behavior 9

Behavior rules
SubjectWhenEffectModeSource
IN 2unpatchedreceives IN 1 signal—914
Bernoulli gatetrigger, heads outcometrigger sent to A—914
Bernoulli gatetrigger, tails outcometrigger sent to B—914
Probabilityextreme settingsbehaves like VC switch—914
Bernoulli gatetoggle modeheads keeps same outputToggle mode914
Bernoulli gatetoggle modetails switches outputToggle mode914
Probabilitymaximum in toggle modealternates outputs A, BToggle mode914
outputslatch modestay +5V until other firesLatch mode914
Toggle/Latchpower offsettings kept—914

Functions 1

Function tags
FunctionBasisScopeEvidenceSource
Probability / Bernoulli GateblockpatchableBernoulli gate: coin toss routes trigger914

Power

+12 V10 mA
−12 V1 mA
+5 V—
Width6 HP
Depth25 mm

Other Probability / Bernoulli Gate modules

All Probability / Bernoulli Gate modules →

Sources 2

  1. [914]
    Branches Manual (full) ↗manual · primary
    ● verified 2026-05-24
  2. [915]
    Mutable Instruments Branches product page ↗product page
    ● verified 2026-05-24