doepfer/a-160-2
Doepfer A-160-2 Clock Divider / Multiplier
4 HP clock divider / multiplier by Doepfer: 2 inputs, 7 outputs, 6 controls, 6 modes.
Inputs 2
| Jack | What it does | Range | Connections |
|---|---|---|---|
| Clock In 1842 | clock input clock, trigger, gate | — | → Clock Divider |
| Reset In 1842 | reset input gate, trigger | threshold 2.5 V | → Clock Divider |
The documents don't state: voltage, impedance (all inputs); threshold (Clock In).
Outputs 7
| Jack | What it does | Range | Connections |
|---|---|---|---|
| Div 1 1842 inferred from the documents | divided clock output 1 clock, gate, trigger | 0 to 10 V | from Clock Divider selected by Divider Set switch = power of two, Divider Set switch = prime numbers, Divider Set switch = integer In 3 modes
|
| Div 2 1842 inferred from the documents | divided clock output 2 clock, gate, trigger | 0 to 10 V | from Clock Divider selected by Divider Set switch = power of two, Divider Set switch = prime numbers, Divider Set switch = integer In 3 modes
|
| Div 3 1842 inferred from the documents | divided clock output 3 clock, gate, trigger | 0 to 10 V | from Clock Divider selected by Divider Set switch = power of two, Divider Set switch = prime numbers, Divider Set switch = integer In 3 modes
|
| Div 4 1842 inferred from the documents | divided clock output 4 clock, gate, trigger | 0 to 10 V | from Clock Divider selected by Divider Set switch = power of two, Divider Set switch = prime numbers, Divider Set switch = integer In 3 modes
|
| Div 5 1842 inferred from the documents | divided clock output 5 clock, gate, trigger | 0 to 10 V | from Clock Divider selected by Divider Set switch = power of two, Divider Set switch = prime numbers, Divider Set switch = integer In 3 modes
|
| Div 6 1842 inferred from the documents | divided clock output 6 clock, gate, trigger | 0 to 10 V | from Clock Divider selected by Divider Set switch = power of two, Divider Set switch = prime numbers, Divider Set switch = integer In 3 modes
|
| Div 7 1842 inferred from the documents | divided clock output 7 clock, gate, trigger | 0 to 10 V | from Clock Divider selected by Divider Set switch = power of two, Divider Set switch = prime numbers, Divider Set switch = integer In 3 modes
|
The documents don't state: pulse, impedance (all outputs).
Controls 6
| Control | What it does | Affects | Positions |
|---|---|---|---|
| Divider Set switch 1842 | dividing factor set switch | Clock Divider, Div 1, Div 2, Div 3, Div 4, Div 5, Div 6, Div 7 |
|
| Output mode switch 1842 | gate/trigger output mode switch | Div 1, Div 2, Div 3, Div 4, Div 5, Div 6, Div 7 |
|
| Clock edge jumper 1842 | clock edge type jumper | Clock Divider |
|
| Reset trigger jumper 1842 | reset level/edge jumper | Reset In |
|
| Reset polarity jumper 1842 | reset polarity jumper | Reset In |
|
| Output polarity jumper 1842 | output polarity jumper | Div 1, Div 2, Div 3, Div 4, Div 5, Div 6, Div 7 |
|
Blocks 1
| Block | Kind | Types | Inputs | Controls | Outputs | Source |
|---|---|---|---|---|---|---|
| Clock Divider | clock divider | Clock divider / multiplier | Clock In, Reset In | Divider Set switch, Output mode switch, Clock edge jumper, Reset trigger jumper, Reset polarity jumper, Output polarity jumper | Div 1, Div 2, Div 3, Div 4, Div 5, Div 6, Div 7 | 1842 |
Modes 6
| Mode | Kind | Selected by | Selection method | Source |
|---|---|---|---|---|
| power of two | divider set | Divider Set switch = power of two | three-position switch | 1842 |
| prime numbers | divider set | Divider Set switch = prime numbers | three-position switch | 1842 |
| integer | divider set | Divider Set switch = integer | three-position switch | 1842 |
| Gate | output mode | Output mode switch = Gate | toggle switch | 1842 |
| Trigger | output mode | Output mode switch = Trigger | toggle switch | 1842 |
| Cst | output mode | Output mode switch = Cst | toggle switch center | 1842 |
Specs 11
| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 4 HP | — | 1842 |
| module | depth | 35 mm | — | 1842 |
| module | +12V current | 50 mA | — | 1842 |
| module | -12V current | 0 mA | — | 1842 |
| Clock Divider | division ratio | 2 to 128 ratio | power of two | 1842 |
| Clock Divider | division ratio | 2 to 17 ratio | prime numbers | 1842 |
| Clock Divider | division ratio | 2 to 8 ratio | integer | 1842 |
| Reset In | high threshold | 2.5 V | positive reset jumper | 1842 |
| Reset In | low threshold | 1 V | negative reset jumper | 1842 |
| outputs | high level | 10 V | about | 1842 |
| outputs | low level | 0 V | — | 1842 |
Properties 5
Behavior 8
| Subject | When | Effect | Mode | Source |
|---|---|---|---|---|
| all outputs | reset signal sensed | set to mode-dependent levels | — | 1842 |
| outputs | Trigger mode | AND-wired with clock | Trigger | 1842 |
| output pulsewidth | Trigger mode | follows clock pulsewidth | Trigger | 1842 |
| outputs | Gate mode | act as binary dividers | Gate | 1842 |
| outputs | Cst position selected | no function yet | Cst | 1842 |
| outputs | output polarity jumper negative | all seven inverted | — | 1842 |
| Reset | positive, level jumper | high level >2.5V resets | — | 1842 |
| Reset | negative, level jumper | low level <1V resets | — | 1842 |
Functions 1
| Function | Basis | Scope | Evidence | Source |
|---|---|---|---|---|
| Clock Divider / Multiplier | block | patchable | block Clock Divider: three factor sets | 1842 |
Power
| +12 V | 50 mA |
|---|---|
| −12 V | 0 mA |
| +5 V | — |
| Width | 4 HP |
| Depth | 35 mm |
Other Clock Divider / Multiplier modules
Sources 1
- [1842]