alm-busy-circuits/quaid-megaslope
ALM Busy Circuits Quaid Megaslope Function Generator · LFO
19 HP function generator and LFO by ALM Busy Circuits: 12 inputs, 4 outputs, 16 controls, 3 modes.
ALM Busy Circuits · ALM020 'Quaid Megaslope' Operation Manual (PDF) ↗
Function Generator · ADSR Envelope · Looping / Cycling Envelope · LFO · Step Sequencer · End-of-Cycle / End-of-Rise Output · Unipolar/bipolar switch
Inputs 12
| Jack | What it does | Range | Connections |
|---|---|---|---|
| Trig 381 | trigger input trigger, clock | — | → Megaslope In 2 modes
|
| Gate 381 | gate input gate | — | → Megaslope In 2 modes
|
| Level CV 1 381 | stage 1 level CV cv | 0 to 5 V, unipolar | → Level 1 |
| Time CV 1 381 | stage 1 time CV cv | 0 to 5 V, unipolar | → Time 1 |
| Level CV 2 381 | stage 2 level CV cv | 0 to 5 V, unipolar | → Level 2 |
| Time CV 2 381 | stage 2 time CV cv | 0 to 5 V, unipolar | → Time 2 |
| Level CV 3 381 | stage 3 level CV cv | 0 to 5 V, unipolar | → Level 3 |
| Time CV 3 381 | stage 3 time CV cv | 0 to 5 V, unipolar | → Time 3 |
| Level CV 4 381 | stage 4 level CV cv | 0 to 5 V, unipolar | → Level 4 |
| Time CV 4 381 | stage 4 time CV cv | 0 to 5 V, unipolar | → Time 4 |
| Level CV 5 381 | stage 5 level CV cv | 0 to 5 V, unipolar | → Level 5 |
| Time CV 5 381 | stage 5 time CV cv | 0 to 5 V, unipolar | → Time 5 |
The documents don't state: scaling, threshold (all inputs); coupling, impedance (Level CV 1, Time CV 1, Level CV 2, Time CV 2, Level CV 3, Time CV 3, Level CV 4, Time CV 4, Level CV 5, Time CV 5).
Outputs 4
| Jack | What it does | Range | Connections |
|---|---|---|---|
| +Out 381 | main unipolar output cv | 0 to 8 V, unipolar | from Megaslope |
| +/-Out 381 | bipolar output cv | -5 to 5 V, bipolar | from Megaslope |
| EOC 381 | end of cycle trigger trigger | — | from Megaslope |
| End of Stage 382 inferred from the documents | end of stage trigger trigger | — | from Megaslope |
The documents don't state: voltage (EOC, End of Stage); pulse, coupling, impedance (all outputs).
Controls 16
| Control | What it does | Affects | Positions |
|---|---|---|---|
| Mode 381 | operating mode select button | Megaslope |
|
| Level 1 381 | stage destination level knob | Megaslope | — |
| Time 1 381 | stage time knob | Megaslope | — |
| Slope 1 381 | stage curve log/lin/exp knob | Megaslope |
|
| Level 2 381 | stage destination level knob | Megaslope | — |
| Time 2 381 | stage time knob | Megaslope | — |
| Slope 2 381 | stage curve log/lin/exp knob | Megaslope |
|
| Level 3 381 | stage destination level knob | Megaslope | — |
| Time 3 381 | stage time knob | Megaslope | — |
| Slope 3 381 | stage curve log/lin/exp knob | Megaslope |
|
| Level 4 381 | stage destination level knob | Megaslope | — |
| Time 4 381 | stage time knob | Megaslope | — |
| Slope 4 381 | stage curve log/lin/exp knob | Megaslope |
|
| Level 5 381 | stage destination level knob | Megaslope | — |
| Time 5 381 | stage time knob | Megaslope | — |
| Slope 5 381 | stage curve log/lin/exp knob | Megaslope |
|
Blocks 1
| Block | Kind | Types | Inputs | Controls | Outputs | Source |
|---|---|---|---|---|---|---|
| Megaslope | five stage function generator | Function generator, Envelope generator, LFO, Step sequencer | Trig, Gate, Level CV 1, Time CV 1, Level CV 2, Time CV 2, Level CV 3, Time CV 3, Level CV 4, Time CV 4, Level CV 5, Time CV 5 | Mode, Level 1, Time 1, Slope 1, Level 2, Time 2, Slope 2, Level 3, Time 3, Slope 3, Level 4, Time 4, Slope 4, Level 5, Time 5, Slope 5 | +Out, +/-Out, EOC, End of Stage | 381 |
Modes 3
Specs 10
| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| Time | stage time | 1 to 2 ms | fully CCW | 381 |
| Time | stage time | 100 ms | 12 o'clock | 381 |
| Time | stage time | 3 s | 9 o'clock (as printed) | 381 |
| Time | stage time | 3 min | 5 o'clock (max) | 381 |
| Megaslope | stage count | 5 stages | — | 381 |
| module | current +12V | 70 mA | — | 381 |
| module | current -12V | 35 mA | — | 381 |
| module | width | 19 HP | — | 381 |
| module | depth | 38 mm | manual | 381 |
| module | depth | 32 mm | product page | 382 |
Properties 4
Behavior 12
| Subject | When | Effect | Mode | Source |
|---|---|---|---|---|
| Gate | held high | sustains at selected stage | Env | 381 |
| Gate | low before sustain stage | envelope ends immediately | Env | 381 |
| Envelope | retriggered mid-cycle | starts from current level | Env | 381 |
| Trig | trigger received | runs all 5 stages | Env | 381 |
| Trig | trigger received | steps to next stage | Step | 381 |
| Sequence | set stage count reached | cycles to initial stage | Step | 381 |
| Step level | Time above zero | slides to new level | Step | 381 |
| Gate | gate received | resets to first stage | Step | 381 |
| Final stage | cycle end | moves to first level | Loop | 381 |
| Loop | always | cycles automatically | Loop | 381 |
| +/-Out | not active | sits at -5V | — | 381 |
| EOC | full cycle completed | outputs trigger | — | 381 |
Functions 7
| Function | Basis | Scope | Evidence | Source |
|---|---|---|---|---|
| Function Generator | block | patchable | block Megaslope: five stage function generator | 381 |
| ADSR Envelope | mode | patchable | mode Env: 5 stage envelope on +Out | 381 |
| Looping / Cycling Envelope | mode | patchable | mode Loop: stages cycle automatically | 381 |
| LFO | mode | patchable | mode Loop: flexible LFO | 381 |
| Step Sequencer | mode | patchable | mode Step: Trig steps stage levels | 381 |
| End-of-Cycle / End-of-Rise Output | jack | patchable | jack EOC: end of cycle trigger | 381 |
| Unipolar/bipolar switch | jack | patchable | +Out unipolar and +/-Out bipolar outputs | 381 |
Power
| +12 V | 70 mA |
|---|---|
| −12 V | 35 mA |
| +5 V | — |
| Width | 19 HP |
| Depth | 38 mm |
Other Function Generator modules
Sources 2
- [381]
-
[382]
ALM Busy Circuits Quaid Megaslope product page ↗product page⚠ verified 2026-05-15 · the manufacturer changed this document since