alm-busy-circuits/quaid-gigaslope

ALM Busy Circuits Quaid Gigaslope Function Generator · LFO

52 HP function generator and LFO by ALM Busy Circuits: 8 inputs, 6 outputs, 55 controls, 4 modes.

ALM Busy Circuits · ALM047 'Quaid Gigaslope' Operation Manual (PDF) ↗

Function Generator · ADSR Envelope · Looping / Cycling Envelope · LFO · Step Sequencer · End-of-Cycle / End-of-Rise Output · Unipolar/bipolar switch

Inputs 8

Inputs
JackWhat it doesRangeConnections
In1 387trigger input
trigger, gate, clock
threshold 1 V
→ Slope 1
In 3 modes
  • Env: starts slope; gate sustains → Slope 1
  • Loop: resets to first stage → Slope 1
  • Step: advances to next stage → Slope 1
In2 387trigger input
trigger, gate, clock
threshold 1 V
normalled from In1
→ Slope 2
In 3 modes
  • Env: starts slope; gate sustains → Slope 2
  • Loop: resets to first stage → Slope 2
  • Step: advances to next stage → Slope 2
In3 387trigger input
trigger, gate, clock
threshold 1 V
normalled from In2
→ Slope 3
In 3 modes
  • Env: starts slope; gate sustains → Slope 3
  • Loop: resets to first stage → Slope 3
  • Step: advances to next stage → Slope 3
In4 387trigger input
trigger, gate, clock
threshold 1 V
normalled from In3
→ Slope 4
In 3 modes
  • Env: starts slope; gate sustains → Slope 4
  • Loop: resets to first stage → Slope 4
  • Step: advances to next stage → Slope 4
CV In 1 387assignable CV input
cv, trigger, gate
—
→ Level, Time, Reset, Quantiser
CV In 2 387assignable CV input
cv, trigger, gate
—
→ Level, Time, Reset, Quantiser
CV In 3 387assignable CV input
cv, trigger, gate
—
→ Level, Time, Reset, Quantiser
CV In 4 387assignable CV input
cv, trigger, gate
—
→ Level, Time, Reset, Quantiser

The documents don't state: voltage, polarity, scaling, coupling, impedance (all inputs).

Outputs 6

Outputs
JackWhat it doesRangeConnections
Out1 387slope CV output
cv, pitch
-5 to 5 V
from Slope 1, Quantiser
selected by +/- = Unipolar 0-5V, +/- = Bipolar ±5V, +/- = Unipolar 0-2.5V
Out2 387slope CV output
cv, pitch
-5 to 5 V
from Slope 2, Quantiser
selected by +/- = Unipolar 0-5V, +/- = Bipolar ±5V, +/- = Unipolar 0-2.5V
Out3 387slope CV output
cv, pitch
-5 to 5 V
from Slope 3, Quantiser
selected by +/- = Unipolar 0-5V, +/- = Bipolar ±5V, +/- = Unipolar 0-2.5V
Out4 387slope CV output
cv, pitch
-5 to 5 V
from Slope 4, Quantiser
selected by +/- = Unipolar 0-5V, +/- = Bipolar ±5V, +/- = Unipolar 0-2.5V
EOC Out 387end of stage trigger
trigger
≤ 5 V
pulse 200 ms
from Slope 1, Slope 2, Slope 3, Slope 4
EOS Out 387end of slope trigger
trigger
≤ 5 V
pulse 200 ms
from Slope 1, Slope 2, Slope 3, Slope 4

The documents don't state: scaling, coupling, impedance (all outputs).

Controls 55

Controls
ControlWhat it doesAffectsPositions
Slope 387select current slope
button
Slope 1, Slope 2, Slope 3, Slope 4—
Type 387slope mode select
button
Slope 1, Slope 2, Slope 3, Slope 4
  • Env: one-shot envelope
  • Loop: free running loop
  • Step: triggered step sequence
Start 387hold: set start stage
button
Slope 1, Slope 2, Slope 3, Slope 4—
End 387hold: set end stage
button
Slope 1, Slope 2, Slope 3, Slope 4—
Left 387move stage selection left
button
Slope 1, Slope 2, Slope 3, Slope 4—
Right 387move stage selection right
button
Slope 1, Slope 2, Slope 3, Slope 4—
Sustain 387hold: set sustain stage
button
Slope 1, Slope 2, Slope 3, Slope 4—
Quantiser 387cycle quantiser scales
button
Quantiser—
Reset 387reset to first stage
button
Slope 1, Slope 2, Slope 3, Slope 4—
+/- 387output range
button
Out1, Out2, Out3, Out4
  • press (LED on): unipolar 0-5V
  • press (LED off): bipolar ±5V
  • hold (LED flashing): unipolar 0-2.5V
EOC 387toggle EOC trigger
button
EOC Out—
EOS 387toggle EOS trigger
button
EOS Out—
Assign 1 387assign CV input
button
CV In 1—
Assign 2 387assign CV input
button
CV In 2—
Assign 3 387assign CV input
button
CV In 3—
Assign 4 387assign CV input
button
CV In 4—
Level 1 387stage 1 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 1 387stage 1 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 1 387stage 1 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 2 387stage 2 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 2 387stage 2 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 2 387stage 2 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 3 387stage 3 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 3 387stage 3 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 3 387stage 3 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 4 387stage 4 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 4 387stage 4 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 4 387stage 4 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 5 387stage 5 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 5 387stage 5 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 5 387stage 5 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 6 387stage 6 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 6 387stage 6 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 6 387stage 6 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 7 387stage 7 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 7 387stage 7 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 7 387stage 7 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 8 387stage 8 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 8 387stage 8 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 8 387stage 8 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 9 387stage 9 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 9 387stage 9 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 9 387stage 9 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 10 387stage 10 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 10 387stage 10 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 10 387stage 10 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 11 387stage 11 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 11 387stage 11 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 11 387stage 11 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 12 387stage 12 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 12 387stage 12 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 12 387stage 12 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential
Level 13 387stage 13 max level
fader
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Time 13 387stage 13 duration
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4—
Curve 13 387stage 13 curve shape
knob
Stages, Slope 1, Slope 2, Slope 3, Slope 4
  • fully CCW: logarithmic
  • 12 o'clock: linear
  • fully CW: exponential

Blocks 6

Blocks and their connections
BlockKindTypesInputsControlsOutputsSource
Slope 1variable staged slopeFunction generator, Envelope generator, LFO, Step sequencerIn1Slope, Type, Start, End, Sustain, Reset, +/-, EOC, EOS, Level 1, Time 1, Curve 1, Level 2, Time 2, Curve 2, Level 3, Time 3, Curve 3, Level 4, Time 4, Curve 4, Level 5, Time 5, Curve 5, Level 6, Time 6, Curve 6, Level 7, Time 7, Curve 7, Level 8, Time 8, Curve 8, Level 9, Time 9, Curve 9, Level 10, Time 10, Curve 10, Level 11, Time 11, Curve 11, Level 12, Time 12, Curve 12, Level 13, Time 13, Curve 13Out1, EOC Out, EOS Out387
Slope 2variable staged slopeFunction generator, Envelope generator, LFO, Step sequencerIn2Slope, Type, Start, End, Sustain, Reset, +/-, EOC, EOS, Level 1, Time 1, Curve 1, Level 2, Time 2, Curve 2, Level 3, Time 3, Curve 3, Level 4, Time 4, Curve 4, Level 5, Time 5, Curve 5, Level 6, Time 6, Curve 6, Level 7, Time 7, Curve 7, Level 8, Time 8, Curve 8, Level 9, Time 9, Curve 9, Level 10, Time 10, Curve 10, Level 11, Time 11, Curve 11, Level 12, Time 12, Curve 12, Level 13, Time 13, Curve 13Out2, EOC Out, EOS Out387
Slope 3variable staged slopeFunction generator, Envelope generator, LFO, Step sequencerIn3Slope, Type, Start, End, Sustain, Reset, +/-, EOC, EOS, Level 1, Time 1, Curve 1, Level 2, Time 2, Curve 2, Level 3, Time 3, Curve 3, Level 4, Time 4, Curve 4, Level 5, Time 5, Curve 5, Level 6, Time 6, Curve 6, Level 7, Time 7, Curve 7, Level 8, Time 8, Curve 8, Level 9, Time 9, Curve 9, Level 10, Time 10, Curve 10, Level 11, Time 11, Curve 11, Level 12, Time 12, Curve 12, Level 13, Time 13, Curve 13Out3, EOC Out, EOS Out387
Slope 4variable staged slopeFunction generator, Envelope generator, LFO, Step sequencerIn4Slope, Type, Start, End, Sustain, Reset, +/-, EOC, EOS, Level 1, Time 1, Curve 1, Level 2, Time 2, Curve 2, Level 3, Time 3, Curve 3, Level 4, Time 4, Curve 4, Level 5, Time 5, Curve 5, Level 6, Time 6, Curve 6, Level 7, Time 7, Curve 7, Level 8, Time 8, Curve 8, Level 9, Time 9, Curve 9, Level 10, Time 10, Curve 10, Level 11, Time 11, Curve 11, Level 12, Time 12, Curve 12, Level 13, Time 13, Curve 13Out4, EOC Out, EOS Out387
Stages13 shared stages—CV In 1, CV In 2, CV In 3, CV In 4Level 1, Time 1, Curve 1, Level 2, Time 2, Curve 2, Level 3, Time 3, Curve 3, Level 4, Time 4, Curve 4, Level 5, Time 5, Curve 5, Level 6, Time 6, Curve 6, Level 7, Time 7, Curve 7, Level 8, Time 8, Curve 8, Level 9, Time 9, Curve 9, Level 10, Time 10, Curve 10, Level 11, Time 11, Curve 11, Level 12, Time 12, Curve 12, Level 13, Time 13, Curve 13—387
Quantisermusical scale quantiserQuantizer—QuantiserOut1, Out2, Out3, Out4387

Modes 4

Modes
ModeKindSelected bySelection methodSource
Envtriggered envelopeType = EnvType button per slope387
Loopfree running LFOType = LoopType button per slope387
Stepclocked step sequencerType = StepType button per slope387
CalibrationV/Oct calibration—power on holding Left387

Hidden functions 10

Hidden functions
FunctionTriggerAffectsSource
quantisation offhold Quantiser + ResetQuantiser387
scale stephold Quantiser + Left/RightQuantiser387
reinitialise slopeSlope + Type + ResetSlope 1, Slope 2, Slope 3, Slope 4387
assign CVhold Assign + move controlCV In 1, CV In 2, CV In 3, CV In 4387
show assignmentshold AssignCV In 1, CV In 2, CV In 3, CV In 4387
half range 0-2.5Vhold +/-Out1, Out2, Out3, Out4387
shift sequenceLeft/Right without Start/EndSlope 1, Slope 2, Slope 3, Slope 4387
calibrationpower on holding LeftOut1, Out2, Out3, Out4387
factory resetpower on holding Endmodule387
firmware updateUSB to PC unpoweredmodule387

Specs 11

Specs
SubjectQuantityValueConditionSource
modulestage count13 stages—387
moduleslope count4 slopes—387
Quantiserscale count19 scales—387
Timestage time (truncated text)4.5 ms—387
EOC/EOStrigger length200 ms—387
moduleCV inputs4 inputs—387
AXON expanderextra CV inputs4 inputs—387
modulecurrent +12V380 mA—388
modulecurrent -12V30 mA—388
modulewidth52 HP—388
moduledepth32 mm—387

Properties 7

Properties
SubjectPropertyValueSource
stagessharingshared or split387
stage controlsscopeall slopes using stage387
Curverangelog-lin-exp387
Quantiserscaleschromatic, modes, pentatonic, chords387
In1-In4normallingeach normalled to next387
AXONsupported countone387
Out1-Out4default range0-5V387

Behavior 17

Behavior rules
SubjectWhenEffectModeSource
In1In2-4 unpatchedalso triggers slopes 2-4—387
normallinginput patchedchain restarts from patched input—387
Trigger inputabove 1Vstarts/advances/resets slope—387
Trigger inputtrigger receivedresets to first stageLoop387
Slopetriggeredruns onceEnv387
Slopelast stage endsloops indefinitelyLoop387
Sequencelast stage reachedrestarts automaticallyStep387
Sustain stagegate held high (>1V)holds stage levelEnv387
SustainLoop or Step modecannot be set—387
Resetpressed in Env/Loopimmediately to first stage—387
Resetpressed in Stepresets on next triggerStep387
EOC Outany active stage ends200ms trigger—387
EOS Outlast active stage ends200ms trigger—387
EOC/EOSmultiple slopes enabledtriggers from any enabled slope—387
Assignheld, control turned upassigns CV input—387
Assignheld, control turned downunassigns CV input—387
Leveloutput range changedactual voltage scales—387

Functions 7

Function tags
FunctionBasisScopeEvidenceSource
Function Generatorblockpatchableblocks Slope 1-4: variable staged slope387
ADSR Envelopemodepatchablemode Env: one-shot envelope on Out387
Looping / Cycling Envelopemodepatchablemode Loop: staged slope loops indefinitely387
LFOmodepatchablemode Loop: free running LFO387
Step Sequencermodepatchablemode Step: trigger advances stage voltages387
End-of-Cycle / End-of-Rise OutputjackpatchableEOC/EOS trigger outputs387
Unipolar/bipolar switchcontrolpatchable+/- button toggles outputs unipolar 0-5V / bipolar ±5V387

Power

+12 V380 mA
−12 V30 mA
+5 V—
Width52 HP
Depth32 mm

Other Function Generator modules

All Function Generator modules →

Firmware 1

VersionReleasedNotes
1002026-02-02387

Sources 2

  1. [387]
    ALM047 'Quaid Gigaslope' Operation Manual ↗manual · primary
    ● verified 2026-05-15
  2. [388]
    ALM Busy Circuits Quaid Gigaslope product page ↗product page