vermona/fourmulator

Vermona fourMulator Trigger / Euclidean Sequencer · Master Clock

34 HP trigger / euclidean sequencer and master clock by Vermona: 10 inputs, 10 outputs, 13 controls, 3 modes.

Vermona · fourMulator User Manual (EN) (PDF) ↗

LFO · Random / Sample & Hold CV · Master Clock · Tempo / Clock Sync · Clock Divider / Multiplier · End-of-Cycle / End-of-Rise Output · Trigger / Euclidean Sequencer · Phase-offset outputs

Inputs 10

Inputs
JackWhat it doesRangeConnections
CV 1 1134frequency CV
cv
-5 to 5 V, bipolar
→ Modulator 1, SPEED 1 knob
In 1 mode
  • CLK: clock division CV → SPEED 1 knob
RESET 1 1134waveform reset
gate, trigger
≤ 12 V
threshold 3.5 V
→ Modulator 1
CV 2 1134frequency CV
cv
-5 to 5 V, bipolar
→ Modulator 2, SPEED/PHASE 2 knob
In 2 modes
  • SYNC: phase shift CV → SPEED/PHASE 2 knob
  • CLK: clock division CV → SPEED/PHASE 2 knob
RESET 2 1134waveform reset
gate, trigger
≤ 12 V
threshold 3.5 V
→ Modulator 2
CV 3 1134frequency CV
cv
-5 to 5 V, bipolar
→ Modulator 3, SPEED/PHASE 3 knob
In 2 modes
  • SYNC: phase shift CV → SPEED/PHASE 3 knob
  • CLK: clock division CV → SPEED/PHASE 3 knob
RESET 3 1134waveform reset
gate, trigger
≤ 12 V
threshold 3.5 V
→ Modulator 3
CV 4 1134frequency CV
cv
-5 to 5 V, bipolar
→ Modulator 4, SPEED/PHASE 4 knob
In 2 modes
  • SYNC: phase shift CV → SPEED/PHASE 4 knob
  • CLK: clock division CV → SPEED/PHASE 4 knob
RESET 4 1134waveform reset
gate, trigger
≤ 12 V
threshold 3.5 V
→ Modulator 4
CLK IN 1134external clock input
clock
≤ 12 V
threshold 3.5 V
→ clock-generator, Modulator 1, Modulator 2, Modulator 3, Modulator 4
RESET (global) 1134reset all Modulators
gate, trigger
≤ 12 V
threshold 3.5 V
→ Modulator 1, Modulator 2, Modulator 3, Modulator 4

The documents don't state: polarity (RESET 1, RESET 2, RESET 3, RESET 4, CLK IN, RESET (global)); scaling, coupling, audio rate, impedance (all inputs).

Outputs 10

Outputs
JackWhat it doesRangeConnections
WAVE 1 1134selected waveform
cv
-5 to 5 V, bipolar
from Modulator 1
TRIGGER 1 1134trigger per new cycle
trigger
≤ 12 V
pulse 10 ms
from Modulator 1
WAVE 2 1134selected waveform
cv
-5 to 5 V, bipolar
from Modulator 2
TRIGGER 2 1134trigger per new cycle
trigger
≤ 12 V
pulse 10 ms
from Modulator 2
WAVE 3 1134selected waveform
cv
-5 to 5 V, bipolar
from Modulator 3
TRIGGER 3 1134trigger per new cycle
trigger
≤ 12 V
pulse 10 ms
from Modulator 3
WAVE 4 1134selected waveform
cv
-5 to 5 V, bipolar
from Modulator 4
TRIGGER 4 1134trigger per new cycle
trigger
≤ 12 V
pulse 10 ms
from Modulator 4
CLK OUT 1134clock output
clock, trigger
≤ 12 V
pulse 10 ms
from clock-generator
TRIG SEQ 1134trigger-sequence output
trigger
≤ 12 V
pulse 10 ms
from trigger-sequence, Modulator 2, Modulator 3, Modulator 4

The documents don't state: polarity (TRIGGER 1, TRIGGER 2, TRIGGER 3, TRIGGER 4, CLK OUT, TRIG SEQ); scaling, coupling, audio rate, impedance (all outputs).

Controls 13

Controls
ControlWhat it doesAffectsPositions
WAVE 1 knob 1134waveform select
knob
Modulator 1, WAVE 1
  • ascending saw: rising sawtooth
  • descending saw: falling sawtooth
  • square: square wave
  • triangle: triangle wave
  • sine: sine wave
  • random: sample & hold
SPEED 1 knob 1134frequency
knob · 0.05 to 100 Hz
Modulator 1
In 1 mode
  • CLK: clock division select → Modulator 1
SYNC 1 switch 1134sync mode select
switch
Modulator 1
  • OFF: free running at SPEED
  • CLK: synced to clock
WAVE 2 knob 1134waveform select
knob
Modulator 2, WAVE 2
  • ascending saw: rising sawtooth
  • descending saw: falling sawtooth
  • square: square wave
  • triangle: triangle wave
  • sine: sine wave
  • random: sample & hold
SPEED/PHASE 2 knob 1134frequency / phase
knob · 0.05 to 100 Hz
Modulator 2
In 2 modes
  • SYNC: phase 0-180 degrees → Modulator 2
  • CLK: clock division select → Modulator 2
SYNC 2 switch 1134sync mode select
switch
Modulator 2
  • OFF: free running at SPEED
  • SYNC: synced to Modulator 1
  • CLK: synced to clock
WAVE 3 knob 1134waveform select
knob
Modulator 3, WAVE 3
  • ascending saw: rising sawtooth
  • descending saw: falling sawtooth
  • square: square wave
  • triangle: triangle wave
  • sine: sine wave
  • random: sample & hold
SPEED/PHASE 3 knob 1134frequency / phase
knob · 0.05 to 100 Hz
Modulator 3
In 2 modes
  • SYNC: phase 0-180 degrees → Modulator 3
  • CLK: clock division select → Modulator 3
SYNC 3 switch 1134sync mode select
switch
Modulator 3
  • OFF: free running at SPEED
  • SYNC: synced to Modulator 2
  • CLK: synced to clock
WAVE 4 knob 1134waveform select
knob
Modulator 4, WAVE 4
  • ascending saw: rising sawtooth
  • descending saw: falling sawtooth
  • square: square wave
  • triangle: triangle wave
  • sine: sine wave
  • random: sample & hold
SPEED/PHASE 4 knob 1134frequency / phase
knob · 0.05 to 100 Hz
Modulator 4
In 2 modes
  • SYNC: phase 0-180 degrees → Modulator 4
  • CLK: clock division select → Modulator 4
SYNC 4 switch 1134sync mode select
switch
Modulator 4
  • OFF: free running at SPEED
  • SYNC: synced to Modulator 3
  • CLK: synced to clock
TAP 1134tap tempo
button
clock-generator—

Blocks 6

Blocks and their connections
BlockKindTypesInputsControlsOutputsSource
Modulator 1LFOLFO, Random / chaos sourceCV 1, RESET 1WAVE 1 knob, SPEED 1 knob, SYNC 1 switchWAVE 1, TRIGGER 11134
Modulator 2LFOLFO, Random / chaos sourceCV 2, RESET 2WAVE 2 knob, SPEED/PHASE 2 knob, SYNC 2 switchWAVE 2, TRIGGER 21134
Modulator 3LFOLFO, Random / chaos sourceCV 3, RESET 3WAVE 3 knob, SPEED/PHASE 3 knob, SYNC 3 switchWAVE 3, TRIGGER 31134
Modulator 4LFOLFO, Random / chaos sourceCV 4, RESET 4WAVE 4 knob, SPEED/PHASE 4 knob, SYNC 4 switchWAVE 4, TRIGGER 41134
clock-generatorclock generatorClock generatorCLK INTAPCLK OUT1134
trigger-sequencetrigger-sequence———TRIG SEQ1134

Modes 3

Modes
ModeKindSelected bySelection methodSource
OFFModulator sync modeSYNC switch = OFF—1134
SYNCModulator sync modeSYNC switch = SYNC—1134
CLKModulator sync modeSYNC switch = CLK—1134

Hidden functions 2

Hidden functions
FunctionTriggerAffectsSource
phase shiftSYNC switch at SYNCSPEED/PHASE knob1134
clock divisionSYNC switch at CLKSPEED knob, SPEED/PHASE knob1134

Specs 14

Specs
SubjectQuantityValueConditionSource
Modulatorfrequency range0.05 to 100 Hz—1134
Modulatorlongest period20 s—1135
SPEED/PHASEphase shift0 to 180 degreesSYNC mode1134
SPEEDclock division settings8 settingsCLK mode1134
clock division 1/1rate0.25 x incoming clockquarter-note clock1134
clock division 1/16rate4 x incoming clockquarter-note clock1134
clock division 1/32rate8 x incoming clockquarter-note clock1134
WAVE knobwaveforms6 waveforms—1134
TAPtaps for tempo change4 taps—1134
modulecurrent +12V120 mA—1134
modulecurrent -12V10 mA—1134
modulewidth34 HP—1134
moduledepth25 mm—1134
moduleweight365 g—1134

Properties 8

Properties
SubjectPropertyValueSource
Modulatorsimplementationdigital1135
random waveformtypesample & hold1134
Modulator 1sync rolereference only1134
Modulators 2-4sync sourceleft neighbor1134
CV inputscombinationadded to SPEED/PHASE1134
SPEED LEDsindicationlit each new cycle1134
clockresolutionuser-defined, relative1134
power connectorpins10-pole, reverse-protected1134

Behavior 16

Behavior rules
SubjectWhenEffectModeSource
Modulator 1SYNC switchOFF and CLK only—1134
Modulator 2-4SYNC positionfollows left neighbor's speed—1134
SPEED/PHASESYNC positionsets phase 0-180 degreesSYNC1134
SPEEDCLK positionselects clock divisionCLK1134
CV inputSYNC or CLK activemodulates phase or division—1134
CV inputpushes beyond 100 Hzfrequency limited to 100 Hz—1134
RESETtrigger/gate receivedwaveform restarts at start—1134
global RESETModulator RESET patchedthat Modulator ignores global—1134
CLK INpatchedinternal clock disconnected from Modulators—1134
CLK OUTCLK IN patchedstill outputs internal clock—1134
internal clockCLK IN unpatchedresumes previous tempo—1134
tempo settingpower offlost—1134
TAPtapped four timestempo changes—1134
TRIG SEQno Modulator 2-4 syncedinactive—1134
TRIG SEQseveral Modulators syncedtriggers combined per division—1134
synced ModulatorsSPEED LEDsflash with phase delay—1134

Functions 8

Function tags
FunctionBasisScopeEvidenceSource
LFOblockpatchableModulators 1-4: quad LFO, WAVE outputs1134
Random / Sample & Hold CVmodepatchableWAVE random position: sample & hold1134
Master Clockblockpatchableclock-generator, CLK OUT1134
Tempo / Clock SyncjackpatchableCLK IN and TAP; SYNC CLK mode1134
Clock Divider / MultipliermodepatchableCLK mode: eight clock divisions1134
End-of-Cycle / End-of-Rise OutputjackpatchableTRIGGER: trigger each new cycle1134
Trigger / Euclidean SequencerjackpatchableTRIG SEQ: trigger-sequence from synced Modulators1134
Phase-offset outputsmodepatchableSYNC mode: phase shift 0-180 degrees1135

Power

+12 V120 mA
−12 V10 mA
+5 V—
Width34 HP
Depth25 mm

Other Trigger / Euclidean Sequencer modules

All Trigger / Euclidean Sequencer modules →

Sources 2

  1. [1134]
    Vermona fourMulator User Manual (EN) ↗manual · primary
    ● verified 2026-06-04
  2. [1135]
    Vermona fourMulator product page ↗product page