tiptop-audio/buchla-281t
Tiptop Audio Buchla 281t Function Generator · ADSR Envelope
28 HP function generator and ADSR envelope by Tiptop Audio: 16 inputs, 8 outputs, 16 controls, 4 modes.
Tiptop Audio · Buchla 281t manual (PDF) ↗
Function Generator · ADSR Envelope · Looping / Cycling Envelope · End-of-Cycle / End-of-Rise Output · Phase-offset outputs
Inputs 16
| Jack | What it does | Range | Connections |
|---|---|---|---|
| pulse input A 1933 | trigger pulse trigger, gate | — | → Generator A |
| Cycle A 1933 | cycling gate gate | — | → Generator A |
| attack cv in A 1933 | attack time CV cv | — | → Attack A |
| decay cv in A 1933 | decay time CV cv | — | → Decay A |
| pulse input B 1933 | trigger pulse trigger, gate | — | → Generator B |
| Cycle B 1933 | cycling gate gate | — | → Generator B |
| attack cv in B 1933 | attack time CV cv | — | → Attack B |
| decay cv in B 1933 | decay time CV cv | — | → Decay B |
| pulse input C 1933 | trigger pulse trigger, gate | — | → Generator C |
| Cycle C 1933 | cycling gate gate | — | → Generator C |
| attack cv in C 1933 | attack time CV cv | — | → Attack C |
| decay cv in C 1933 | decay time CV cv | — | → Decay C |
| pulse input D 1933 | trigger pulse trigger, gate | — | → Generator D |
| Cycle D 1933 | cycling gate gate | — | → Generator D |
| attack cv in D 1933 | attack time CV cv | — | → Attack D |
| decay cv in D 1933 | decay time CV cv | — | → Decay D |
The documents don't state: voltage, polarity, scaling, coupling, impedance (all inputs).
Outputs 8
| Jack | What it does | Range | Connections |
|---|---|---|---|
| output A 1933 | function output cv | 0 to 10 V, unipolar | from Generator A |
| pulse output A 1933 | end of decay pulse trigger | — | from Generator A |
| output B 1933 | function output cv | 0 to 10 V, unipolar | from Generator B |
| pulse output B 1933 | end of decay pulse trigger | — | from Generator B |
| output C 1933 | function output cv | 0 to 10 V, unipolar | from Generator C |
| pulse output C 1933 | end of decay pulse trigger | — | from Generator C |
| output D 1933 | function output cv | 0 to 10 V, unipolar | from Generator D |
| pulse output D 1933 | end of decay pulse trigger | — | from Generator D |
The documents don't state: voltage, polarity (pulse output A, pulse output B, pulse output C, pulse output D); scaling, coupling, impedance (all outputs).
Controls 16
| Control | What it does | Affects | Positions |
|---|---|---|---|
| Attack A 1933 | attack time knob · 0.001 to 10 s | Generator A | — |
| Decay A 1933 | decay time knob · 0.001 to 10 s | Generator A | — |
| mode switch A 1933 | mode select switch | Generator A |
|
| Trigger button A 1933 | manual trigger button | Generator A | — |
| Attack B 1933 | attack time knob · 0.001 to 10 s | Generator B | — |
| Decay B 1933 | decay time knob · 0.001 to 10 s | Generator B | — |
| mode switch B 1933 | mode select switch | Generator B |
|
| Trigger button B 1933 | manual trigger button | Generator B | — |
| Attack C 1933 | attack time knob · 0.001 to 10 s | Generator C | — |
| Decay C 1933 | decay time knob · 0.001 to 10 s | Generator C | — |
| mode switch C 1933 | mode select switch | Generator C |
|
| Trigger button C 1933 | manual trigger button | Generator C | — |
| Attack D 1933 | attack time knob · 0.001 to 10 s | Generator D | — |
| Decay D 1933 | decay time knob · 0.001 to 10 s | Generator D | — |
| mode switch D 1933 | mode select switch | Generator D |
|
| Trigger button D 1933 | manual trigger button | Generator D | — |
Blocks 4
| Block | Kind | Types | Inputs | Controls | Outputs | Source |
|---|---|---|---|---|---|---|
| Generator A | function generator | Function generator, Envelope generator | pulse input A, Cycle A, attack cv in A, decay cv in A | Attack A, Decay A, mode switch A, Trigger button A | output A, pulse output A | 1933 |
| Generator B | function generator | Function generator, Envelope generator | pulse input B, Cycle B, attack cv in B, decay cv in B | Attack B, Decay B, mode switch B, Trigger button B | output B, pulse output B | 1933 |
| Generator C | function generator | Function generator, Envelope generator | pulse input C, Cycle C, attack cv in C, decay cv in C | Attack C, Decay C, mode switch C, Trigger button C | output C, pulse output C | 1933 |
| Generator D | function generator | Function generator, Envelope generator | pulse input D, Cycle D, attack cv in D, decay cv in D | Attack D, Decay D, mode switch D, Trigger button D | output D, pulse output D | 1933 |
Modes 4
Specs 8
Properties 4
Behavior 10
| Subject | When | Effect | Mode | Source |
|---|---|---|---|---|
| output | pulse received | ramps up to 10V | — | 1933 |
| output | Sustained, pulse maintained | stays high | Sustained | 1933 |
| output | not Sustained | ramps down after attack | — | 1933 |
| output | input pulse terminates | ramps down to 0V | — | 1933 |
| pulse output | end of Decay | transient pulse | — | 1933 |
| generator | Cyclic mode, Decay ends | cycle repeats | Cyclic | 1933 |
| Cycle jack | gate signal applied | generator cycles | — | 1933 |
| Trigger button | pressed | triggers function generator | — | 1933 |
| generators A and B | Quadrature mode | shifted ninety degrees | Quadrature | 1933 |
| generators C and D | Quadrature mode | shifted ninety degrees | Quadrature | 1933 |
Functions 5
| Function | Basis | Scope | Evidence | Source |
|---|---|---|---|---|
| Function Generator | block | patchable | blocks Generator A-D: function generators | 1933 |
| ADSR Envelope | block | patchable | generator attack/decay contour on output | 1933 |
| Looping / Cycling Envelope | mode | patchable | mode Cyclic: cycle repeats | 1933 |
| End-of-Cycle / End-of-Rise Output | jack | patchable | jack pulse output: end of Decay | 1933 |
| Phase-offset outputs | mode | patchable | mode Quadrature: pairs shifted 90 degrees | 1933 |
Power
| +12 V | 160 mA |
|---|---|
| −12 V | 55 mA |
| +5 V | — |
| Width | 28 HP |
| Depth | 32 mm |
Other Function Generator modules
Sources 1
- [1933]