tiptop-audio/buchla-242t
Tiptop Audio Buchla 242t Trigger / Euclidean Sequencer · Master Clock
16 HP trigger / euclidean sequencer and master clock by Tiptop Audio: 5 inputs, 5 outputs, 9 controls.
Tiptop Audio · Buchla 242t manual (PDF) ↗
Master Clock · Trigger / Euclidean Sequencer · Tempo / Clock Sync
Inputs 5
| Jack | What it does | Range | Connections |
|---|---|---|---|
| CLK IN 1928 | external clock clock | — | → pulse matrix |
| RST IN 1928 | reset end stage trigger | — | → pulse matrix |
| start 1928 | start internal clock trigger | — | → pulser |
| stop 1928 | stop internal clock trigger | — | → pulser |
| PERIOD 1928 | period CV cv | — | → pulser attenuated by PERIOD attenuverter |
The documents don't state: voltage, threshold, impedance (all inputs); scaling (PERIOD).
Outputs 5
| Jack | What it does | Range | Connections |
|---|---|---|---|
| ALL OUT 1928 | continuous pulse train trigger, clock | — | from pulser selected by pulse length jumper = Short, pulse length jumper = Long |
| MATRIX 1928 | programmed pulse patterns trigger | — | from pulse matrix |
| ALTER 1 1928 | alternating pulses trigger | — | — |
| ALTER 2 1928 | alternating pulses trigger | — | — |
| RAMP 1928 | continuous ramp wave cv | — | from pulser |
The documents don't state: voltage, impedance (all outputs); polarity (RAMP); pulse (ALTER 1, ALTER 2).
Controls 9
| Control | What it does | Affects | Positions |
|---|---|---|---|
| PERIOD attenuverter 1928 | period CV amount knob · bipolar | PERIOD, pulser | — |
| PERIOD offset 1928 | internal clock period knob · 0.002 to 10 s | pulser | — |
| stop 1928 | manual stop button | pulser | — |
| single pulse 1928 | manual single pulse button | pulser, pulse matrix | — |
| start 1928 | manual start button | pulser | — |
| row encoder 1928 | scroll vertical rows knob | pulse matrix | — |
| column encoder 1928 | scroll horizontal rows knob | pulse matrix | — |
| on/off 1928 | set/clear pulse point button | pulse matrix | — |
| pulse length jumper 1928 | pulse length jumper | ALL OUT, MATRIX, ALTER 1, ALTER 2 |
|
Blocks 2
| Block | Kind | Types | Inputs | Controls | Outputs | Source |
|---|---|---|---|---|---|---|
| pulser | internal clock | Clock generator | start, stop, PERIOD | PERIOD attenuverter, PERIOD offset, stop, single pulse, start | ALL OUT, RAMP | 1928 |
| pulse matrix | 4 x 12 matrix | Trigger / drum sequencer | CLK IN, RST IN | row encoder, column encoder, on/off, pulse length jumper | MATRIX, ALTER 1, ALTER 2 | 1928 |
Specs 8
Properties 6
Behavior 9
| Subject | When | Effect | Mode | Source |
|---|---|---|---|---|
| ALL OUT | any matrix programming | continuous pulse train | — | 1928 |
| RAMP, ALL OUT | CLK IN active | stay on internal clock | — | 1928 |
| RST IN | pulse received | resets end stage | — | 1928 |
| start | pulse received | starts internal clock | — | 1928 |
| stop | pulse received | stops internal clock | — | 1928 |
| pulse length | jumper Short | internal or CLK width | — | 1928 |
| pulse length | jumper Long | fixed 1 ms | — | 1928 |
| on/off | long press | clears matrix | — | 1928 |
| PERIOD | CV applied | increases or decreases rate | — | 1928 |
Functions 3
| Function | Basis | Scope | Evidence | Source |
|---|---|---|---|---|
| Master Clock | block | patchable | pulser: internal clock; ALL OUT | 1928 |
| Trigger / Euclidean Sequencer | block | patchable | pulse matrix: 4 x 12 programmed pulses | 1928 |
| Tempo / Clock Sync | jack | patchable | jack CLK IN: external clock | 1928 |
Power
| +12 V | 130 mA |
|---|---|
| −12 V | 19 mA |
| +5 V | — |
| Width | 16 HP |
| Depth | 45 mm |
Other Trigger / Euclidean Sequencer modules
Sources 1