mutable-instruments/stages

Mutable Instruments Stages LFO · ADSR Envelope

14 HP LFO and ADSR envelope by Mutable Instruments: 13 inputs, 6 outputs, 18 controls, 6 modes.

Mutable Instruments · Stages Manual (full) ↗

ADSR Envelope · Looping / Cycling Envelope · LFO · End-of-Cycle / End-of-Rise Output · Tempo / Clock Sync · Random / Sample & Hold CV · Slew Limiter · Step Sequencer · Gate / Trigger Utility

Inputs 13

Inputs
JackWhat it doesRangeConnections
GATE 1 514gate / group start
gate, trigger, clock
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 1
In 4 modes
  • RAMP: envelope gate → Segment 1
  • STEP: advance trigger → Segment 1
  • looping RAMP: tempo clock → Segment 1
  • HOLD: pulse trigger → Segment 1
TIME/LEVEL CV 1 514time or level CV
cv
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 1, TIME/LEVEL slider 1
In 3 modes
  • RAMP: ramp time → Segment 1
  • STEP: target level → Segment 1
  • HOLD: hold level → Segment 1
GATE 2 514gate / group start
gate, trigger, clock
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 2
In 4 modes
  • RAMP: envelope gate → Segment 2
  • STEP: advance trigger → Segment 2
  • looping RAMP: tempo clock → Segment 2
  • HOLD: pulse trigger → Segment 2
TIME/LEVEL CV 2 514time or level CV
cv
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 2, TIME/LEVEL slider 2
In 3 modes
  • RAMP: ramp time → Segment 2
  • STEP: target level → Segment 2
  • HOLD: hold level → Segment 2
GATE 3 514gate / group start
gate, trigger, clock
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 3
In 4 modes
  • RAMP: envelope gate → Segment 3
  • STEP: advance trigger → Segment 3
  • looping RAMP: tempo clock → Segment 3
  • HOLD: pulse trigger → Segment 3
TIME/LEVEL CV 3 514time or level CV
cv
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 3, TIME/LEVEL slider 3
In 3 modes
  • RAMP: ramp time → Segment 3
  • STEP: target level → Segment 3
  • HOLD: hold level → Segment 3
GATE 4 514gate / group start
gate, trigger, clock
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 4
In 4 modes
  • RAMP: envelope gate → Segment 4
  • STEP: advance trigger → Segment 4
  • looping RAMP: tempo clock → Segment 4
  • HOLD: pulse trigger → Segment 4
TIME/LEVEL CV 4 514time or level CV
cv
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 4, TIME/LEVEL slider 4
In 3 modes
  • RAMP: ramp time → Segment 4
  • STEP: target level → Segment 4
  • HOLD: hold level → Segment 4
GATE 5 514gate / group start
gate, trigger, clock
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 5
In 4 modes
  • RAMP: envelope gate → Segment 5
  • STEP: advance trigger → Segment 5
  • looping RAMP: tempo clock → Segment 5
  • HOLD: pulse trigger → Segment 5
TIME/LEVEL CV 5 514time or level CV
cv
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 5, TIME/LEVEL slider 5
In 3 modes
  • RAMP: ramp time → Segment 5
  • STEP: target level → Segment 5
  • HOLD: hold level → Segment 5
GATE 6 514gate / group start
gate, trigger, clock
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 6
In 4 modes
  • RAMP: envelope gate → Segment 6
  • STEP: advance trigger → Segment 6
  • looping RAMP: tempo clock → Segment 6
  • HOLD: pulse trigger → Segment 6
TIME/LEVEL CV 6 514time or level CV
cv
coupling dc
audio rate no
impedance 100000 Ω
→ Segment 6, TIME/LEVEL slider 6
In 3 modes
  • RAMP: ramp time → Segment 6
  • STEP: target level → Segment 6
  • HOLD: hold level → Segment 6
Chain connector 515daisy-chain link—
→ Segment 1

The documents don't state: voltage (TIME/LEVEL CV 1, TIME/LEVEL CV 2, TIME/LEVEL CV 3, TIME/LEVEL CV 4, TIME/LEVEL CV 5, TIME/LEVEL CV 6); polarity (GATE 1, TIME/LEVEL CV 1, GATE 2, TIME/LEVEL CV 2, GATE 3, TIME/LEVEL CV 3, GATE 4, TIME/LEVEL CV 4, GATE 5, TIME/LEVEL CV 5, GATE 6, TIME/LEVEL CV 6); scaling, threshold (all inputs).

Outputs 6

Outputs
JackWhat it doesRangeConnections
Output 1 514segment output
cv, gate
-8 to 8 V, bipolar
coupling dc
from Segment 1
In 2 modes
  • group first segment: envelope signal
  • group later segment: segment activity ramp
Output 2 514segment output
cv, gate
-8 to 8 V, bipolar
coupling dc
from Segment 2
In 2 modes
  • group first segment: envelope signal
  • group later segment: segment activity ramp
Output 3 514segment output
cv, gate
-8 to 8 V, bipolar
coupling dc
from Segment 3
In 2 modes
  • group first segment: envelope signal
  • group later segment: segment activity ramp
Output 4 514segment output
cv, gate
-8 to 8 V, bipolar
coupling dc
from Segment 4
In 2 modes
  • group first segment: envelope signal
  • group later segment: segment activity ramp
Output 5 514segment output
cv, gate
-8 to 8 V, bipolar
coupling dc
from Segment 5
In 2 modes
  • group first segment: envelope signal
  • group later segment: segment activity ramp
Output 6 514segment output
cv, gate
-8 to 8 V, bipolar
coupling dc
from Segment 6
In 2 modes
  • group first segment: envelope signal
  • group later segment: segment activity ramp

The documents don't state: scaling, pulse, audio rate, impedance (all outputs).

Controls 18

Controls
ControlWhat it doesAffectsPositions
TIME/LEVEL slider 1 514time or level
fader
Segment 1
In 4 modes
  • RAMP: ramp time → Segment 1
  • STEP: target level 0-8V → Segment 1
  • HOLD: level 0-8V → Segment 1
  • looping RAMP, GATE patched: clock div/mult 1/4-4 → Segment 1
Potentiometer [A] 1 514curve, glide or duration
knob
Segment 1
In 4 modes
  • RAMP: curve shape → Segment 1
  • looping RAMP: LFO waveform → Segment 1
  • STEP: glide amount → Segment 1
  • HOLD: duration → Segment 1
Button [B] 1 514segment type, loop
button
Segment 1
  • press: cycle segment type
  • hold 1s: toggle loop
TIME/LEVEL slider 2 514time or level
fader
Segment 2
In 4 modes
  • RAMP: ramp time → Segment 2
  • STEP: target level 0-8V → Segment 2
  • HOLD: level 0-8V → Segment 2
  • looping RAMP, GATE patched: clock div/mult 1/4-4 → Segment 2
Potentiometer [A] 2 514curve, glide or duration
knob
Segment 2
In 4 modes
  • RAMP: curve shape → Segment 2
  • looping RAMP: LFO waveform → Segment 2
  • STEP: glide amount → Segment 2
  • HOLD: duration → Segment 2
Button [B] 2 514segment type, loop
button
Segment 2
  • press: cycle segment type
  • hold 1s: toggle loop
TIME/LEVEL slider 3 514time or level
fader
Segment 3
In 4 modes
  • RAMP: ramp time → Segment 3
  • STEP: target level 0-8V → Segment 3
  • HOLD: level 0-8V → Segment 3
  • looping RAMP, GATE patched: clock div/mult 1/4-4 → Segment 3
Potentiometer [A] 3 514curve, glide or duration
knob
Segment 3
In 4 modes
  • RAMP: curve shape → Segment 3
  • looping RAMP: LFO waveform → Segment 3
  • STEP: glide amount → Segment 3
  • HOLD: duration → Segment 3
Button [B] 3 514segment type, loop
button
Segment 3
  • press: cycle segment type
  • hold 1s: toggle loop
TIME/LEVEL slider 4 514time or level
fader
Segment 4
In 4 modes
  • RAMP: ramp time → Segment 4
  • STEP: target level 0-8V → Segment 4
  • HOLD: level 0-8V → Segment 4
  • looping RAMP, GATE patched: clock div/mult 1/4-4 → Segment 4
Potentiometer [A] 4 514curve, glide or duration
knob
Segment 4
In 4 modes
  • RAMP: curve shape → Segment 4
  • looping RAMP: LFO waveform → Segment 4
  • STEP: glide amount → Segment 4
  • HOLD: duration → Segment 4
Button [B] 4 514segment type, loop
button
Segment 4
  • press: cycle segment type
  • hold 1s: toggle loop
TIME/LEVEL slider 5 514time or level
fader
Segment 5
In 4 modes
  • RAMP: ramp time → Segment 5
  • STEP: target level 0-8V → Segment 5
  • HOLD: level 0-8V → Segment 5
  • looping RAMP, GATE patched: clock div/mult 1/4-4 → Segment 5
Potentiometer [A] 5 514curve, glide or duration
knob
Segment 5
In 4 modes
  • RAMP: curve shape → Segment 5
  • looping RAMP: LFO waveform → Segment 5
  • STEP: glide amount → Segment 5
  • HOLD: duration → Segment 5
Button [B] 5 514segment type, loop
button
Segment 5
  • press: cycle segment type
  • hold 1s: toggle loop
TIME/LEVEL slider 6 514time or level
fader
Segment 6
In 4 modes
  • RAMP: ramp time → Segment 6
  • STEP: target level 0-8V → Segment 6
  • HOLD: level 0-8V → Segment 6
  • looping RAMP, GATE patched: clock div/mult 1/4-4 → Segment 6
Potentiometer [A] 6 514curve, glide or duration
knob
Segment 6
In 4 modes
  • RAMP: curve shape → Segment 6
  • looping RAMP: LFO waveform → Segment 6
  • STEP: glide amount → Segment 6
  • HOLD: duration → Segment 6
Button [B] 6 514segment type, loop
button
Segment 6
  • press: cycle segment type
  • hold 1s: toggle loop

Blocks 6

Blocks and their connections
BlockKindTypesInputsControlsOutputsSource
Segment 1segmentEnvelope generator, LFO, Sample & hold, Slew limiter / lagGATE 1, TIME/LEVEL CV 1TIME/LEVEL slider 1, Potentiometer [A] 1, Button [B] 1Output 1514
Segment 2segmentEnvelope generator, LFO, Sample & hold, Slew limiter / lagGATE 2, TIME/LEVEL CV 2TIME/LEVEL slider 2, Potentiometer [A] 2, Button [B] 2Output 2514
Segment 3segmentEnvelope generator, LFO, Sample & hold, Slew limiter / lagGATE 3, TIME/LEVEL CV 3TIME/LEVEL slider 3, Potentiometer [A] 3, Button [B] 3Output 3514
Segment 4segmentEnvelope generator, LFO, Sample & hold, Slew limiter / lagGATE 4, TIME/LEVEL CV 4TIME/LEVEL slider 4, Potentiometer [A] 4, Button [B] 4Output 4514
Segment 5segmentEnvelope generator, LFO, Sample & hold, Slew limiter / lagGATE 5, TIME/LEVEL CV 5TIME/LEVEL slider 5, Potentiometer [A] 5, Button [B] 5Output 5514
Segment 6segmentEnvelope generator, LFO, Sample & hold, Slew limiter / lagGATE 6, TIME/LEVEL CV 6TIME/LEVEL slider 6, Potentiometer [A] 6, Button [B] 6Output 6514

Modes 6

Modes
ModeKindSelected bySelection methodSource
RAMPsegment typeButton [B] = presspress button [B]515
HOLDsegment typeButton [B] = presspress button [B]515
STEPsegment typeButton [B] = presspress button [B]515
single-segment looploopButton [B] = hold 1shold button [B] 1s514
multi-segment looploop—press first+last [B]514
segment groupgrouping—patch GATE inputs514

Hidden functions 4

Hidden functions
FunctionTriggerAffectsSource
loop segmenthold [B] 1 secondSegment514
multi-segment looppress [B] of first+lastSegment group514
disable loophold [B] of loop endSegment group514
firmware updatepower on holding last [B]module514

Specs 17

Specs
SubjectQuantityValueConditionSource
CV outputvoltage range0 to 8 V—515
CV outputnegative range-8 to 0 VHOLD/STEP CV modulated515
segmentduration0.001 to 16 s—515
STEP/HOLD levelvoltage range0 to 8 V—514
looping RAMPclock div/mult0.25 to 4 ratioGATE patched514
segment activityramp range0 to 8 V—514
inputsimpedance100000 ohm—515
inputsbandwidth0 to 2000 Hz—515
modulerefresh rate31250 Hz—515
CV captureresolution16 bit—515
CV generationresolution14 bit—515
CV generationerror≤ 2 mV—515
chainmax modules6 modules—514
modulewidth14 HP—515
moduledepth25 mm—515
module+12V current80 mA—514
module-12V current20 mA—514

Properties 6

Properties
SubjectPropertyValueSource
segmentsgroupingby patched GATE inputs514
RAMP curveshapesaccelerating, uniform, decelerating514
looping RAMPwaveformssaw/triangle, sine, trapezoid514
chained modulesbehaviorsingle larger Stages514
processortypeSTM32F373 @ 72 MHz515
DACtypeDAC8168515

Behavior 24

Behavior rules
SubjectWhenEffectModeSource
GATEpatchedstarts new segment group—514
unpatched segmentsright of patched GATEjoin that group—514
group first outputgroup activeoutputs envelope—514
group later outputssegment active8V-to-0V activity ramp—514
segmentsno GATE patchedall independent, free running—514
first RAMPenvelope startramps up to 8V—514
last RAMPenvelope endramps down to 0V—514
RAMP end levelHOLD/STEP adjacentset by that level—514
RAMP end levelnot set by rulesset by potentiometer [A]—514
loopGATE highloop plays—514
loopGATE goes lowcontinue after loop end—514
loopincludes last segmentloops forever—514
envelopereaches STEP segmentwaits for next trigger—514
loopcontains STEP segmentcannot escape loop—514
loopspans different groupsnot allowed—514
single RAMPnot loopingdecay envelope—514
looping single RAMPGATE unpatchedfree LFO, slider rate—514
looping single RAMPGATE patchedtempo-synced LFO—514
single STEPGATE rising edgesample and hold—514
single STEPGATE unpatchedtracks with glide—514
single HOLDGATE patchedpulse generator—514
single HOLDGATE patched, loopingpulse lasts gate length—514
single HOLDGATE unpatchedCV delay—514
HOLD/STEP outputCV modulated negativedown to -8V—515

Functions 9

Function tags
FunctionBasisScopeEvidenceSource
ADSR Envelopeblockpatchablesegment group envelope on output514
Looping / Cycling Envelopemodepatchablesegment loop via button [B]514
LFOmodepatchablelooping single RAMP segment514
End-of-Cycle / End-of-Rise Outputjackpatchablesecondary outputs: segment activity514
Tempo / Clock Syncmodepatchablelooping RAMP follows GATE tempo514
Random / Sample & Hold CVmodepatchablesingle STEP: sample and hold514
Slew Limiterdocumented usepatchabledocumented: Step can slew CV515
Step Sequencerdocumented usepatchabledocumented: STEP segments for step sequences515
Gate / Trigger Utilitymodepatchablesingle HOLD: pulse generator514

Power

+12 V80 mA
−12 V20 mA
+5 V—
Width14 HP
Depth25 mm

Other LFO modules

All LFO modules →

Sources 2

  1. [514]
    Stages Manual (full) ↗manual · primary
    ● verified 2026-05-19
  2. [515]
    Mutable Instruments Stages product page ↗product page
    ● verified 2026-05-19