make-noise/rene
Make Noise René Step Sequencer · Quantizer
34 HP step sequencer and quantizer by Make Noise: 8 inputs, 6 outputs, 53 controls, 10 modes.
Make Noise · René Manual (current; the post-Classic three-channel sequencer) (PDF) ↗
Step Sequencer · Quantizer · Random / Sample & Hold CV · Slew Limiter
Inputs 8
| Jack | What it does | Range | Connections |
|---|---|---|---|
| X-CLK 238 | X clock clock, gate | threshold 2.5 V pulse 2.5 ms | → X/Red Channel, C/Orange Channel |
| X-MOD 238 | X MODifier gate gate, trigger | threshold 2.5 V pulse 2.5 ms | → X/Red Channel, C/Orange Channel In 4 modes
|
| X-CV (in) 238 | X control voltage cv | 0 to 5 V, unipolar | normalled from +5V → X/Red Channel, C/Orange Channel attenuated by X-CV Combo Pot In 4 modes
|
| Y-CLK 238 | Y clock clock, gate | threshold 2.5 V pulse 2.5 ms | → Y/Green Channel, C/Orange Channel |
| Y-MOD 238 | Y MODifier gate gate, trigger | threshold 2.5 V pulse 2.5 ms | → Y/Green Channel, C/Orange Channel In 4 modes
|
| Y-CV (in) 238 | Y control voltage cv | 0 to 5 V, unipolar | normalled from +5V → Y/Green Channel, C/Orange Channel attenuated by Y-CV Combo Pot In 4 modes
|
| Z-MOD 238 | next enabled STATE gate, trigger | threshold 2.5 V pulse 2.5 ms | → Z Axis |
| Z-CV 238 | STATE select, Global Reset cv | 0 to 5 V, unipolar | → Z Axis |
The documents don't state: voltage, polarity (X-CLK, X-MOD, Y-CLK, Y-MOD, Z-MOD); impedance (all inputs).
Outputs 6
| Jack | What it does | Range | Connections |
|---|---|---|---|
| X-CV (out) 238 | X sequence CV cv, pitch | unipolar scaling v oct | from X/Red Channel, Quantizer |
| X-G 238 | X gate output gate, trigger | 0 to 8 V, unipolar | from X/Red Channel In 2 modes
|
| Y-CV (out) 238 | Y sequence CV cv, pitch | unipolar scaling v oct | from Y/Green Channel, Quantizer |
| Y-G 238 | Y gate output gate, trigger | 0 to 8 V, unipolar | from Y/Green Channel In 2 modes
|
| C-CV (out) 238 | C sequence CV cv, pitch | unipolar scaling v oct | from C/Orange Channel, Quantizer |
| C-G 238 | C gate output gate, trigger | 0 to 8 V, unipolar | from C/Orange Channel In 2 modes
|
The documents don't state: voltage (X-CV (out), Y-CV (out), C-CV (out)); impedance (all outputs).
Controls 53
| Control | What it does | Affects | Positions |
|---|---|---|---|
| CV Knob 1 238 | location 1 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 2 238 | location 2 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 3 238 | location 3 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 4 238 | location 4 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 5 238 | location 5 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 6 238 | location 6 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 7 238 | location 7 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 8 238 | location 8 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 9 238 | location 9 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 10 238 | location 10 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 11 238 | location 11 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 12 238 | location 12 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 13 238 | location 13 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 14 238 | location 14 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 15 238 | location 15 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| CV Knob 16 238 | location 16 CV value knob | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| Button 1 238 | grid location 1 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 2 238 | grid location 2 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 3 238 | grid location 3 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 4 238 | grid location 4 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 5 238 | grid location 5 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 6 238 | grid location 6 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 7 238 | grid location 7 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 8 238 | grid location 8 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 9 238 | grid location 9 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 10 238 | grid location 10 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 11 238 | grid location 11 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 12 238 | grid location 12 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 13 238 | grid location 13 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 14 238 | grid location 14 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 15 238 | grid location 15 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| Button 16 238 | grid location 16 button | X/Red Channel, Y/Green Channel, C/Orange Channel, Z Axis | — |
| X-CV Combo Pot 238 | X-CV attenuator, 5V offset knob | X-CV (in) | — |
| Y-CV Combo Pot 238 | Y-CV attenuator, 5V offset knob | Y-CV (in) | — |
| X Channel Button 238 | select X channel, Latch button | X/Red Channel | — |
| Y Channel Button 238 | select Y channel, Latch button | Y/Green Channel | — |
| C Channel Button 238 | select C channel, Latch button | C/Orange Channel | — |
| Left Button 238 | previous Program Page button | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| Right Button 238 | next Program Page button | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| FUN.OP.SLEEP 238 | non-ACCESS location behavior menu setting | X/Red Channel, Y/Green Channel, C/Orange Channel |
|
| FUN.OP.TRIG 238 | gate width, gate ties menu setting | X-G, Y-G, C-G |
|
| FUN.OP.SCAN 238 | write knobs to channel menu setting | X/Red Channel, Y/Green Channel, C/Orange Channel | — |
| FUN.MOD.RESET 238 | MOD resets channel menu setting | X/Red Channel, Y/Green Channel, C/Orange Channel |
|
| FUN.MOD.CLK 238 | MOD adds clocks menu setting | X/Red Channel, Y/Green Channel, C/Orange Channel |
|
| FUN.MOD.RUNSTP 238 | MOD runs/stops channel menu setting | X/Red Channel, Y/Green Channel, C/Orange Channel |
|
| FUN.CV.ADD 238 | CV added to location menu setting | X/Red Channel, Y/Green Channel |
|
| FUN.CV.LOC 238 | CV addresses location menu setting | X/Red Channel, Y/Green Channel, C/Orange Channel |
|
| FUN.CV.SNAKE 238 | CV selects Snake pattern menu setting | X/Red Channel, Y/Green Channel |
|
| FUN.CV.S&H 238 | MOD-sampled CV add menu setting | X/Red Channel, Y/Green Channel |
|
| GL.Z.ON 238 | Z inputs always active menu setting | Z Axis |
|
| GBL.Z.RESET 238 | State change resets channels menu setting | Z Axis, X/Red Channel, Y/Green Channel, C/Orange Channel |
|
| GBL.BUS 238 | Select Bus behavior menu setting | Select Bus |
|
| GBL.STORE 238 | store all States menu setting | Z Axis | — |
Blocks 6
| Block | Kind | Types | Inputs | Controls | Outputs | Source |
|---|---|---|---|---|---|---|
| X/Red Channel | Snake channel | Step sequencer | X-CLK, X-MOD, X-CV (in) | X Channel Button | X-CV (out), X-G | 238 |
| Y/Green Channel | Snake channel | Step sequencer | Y-CLK, Y-MOD, Y-CV (in) | Y Channel Button | Y-CV (out), Y-G | 238 |
| C/Orange Channel | Cartesian channel | Step sequencer | X-CLK, Y-CLK, X-MOD, Y-MOD, X-CV (in), Y-CV (in) | C Channel Button | C-CV (out), C-G | 238 |
| Quantizer | onboard quantizer (per channel) | Quantizer | X-CV (in), Y-CV (in) | — | X-CV (out), Y-CV (out), C-CV (out) | 238 |
| Z Axis | STATE selection | — | Z-MOD, Z-CV | Left Button, Right Button | — | 238 |
| Select Bus | Select Bus | — | — | — | — | 238 |
Modes 10
| Mode | Kind | Selected by | Selection method | Source |
|---|---|---|---|---|
| ACCESS | Program Page | — | Left/Right buttons | 238 |
| GATE | Program Page | — | Left/Right buttons | 238 |
| GLIDE | Program Page | — | Left/Right buttons | 238 |
| SNAKE | Program Page | — | Left/Right buttons | 238 |
| FUN | Program Page | — | Left/Right buttons | 238 |
| QUANT | Program Page | — | Left/Right buttons | 238 |
| LATCH | Latch page | — | press current channel button | 238 |
| Select STATE | State page | Y Channel Button = State Pages | Left+Right, then Y | 238 |
| M-Paste | State page | X Channel Button = State Pages | Left+Right, then X | 238 |
| Global | State page | C Channel Button = State Pages | Left+Right, then C | 238 |
Specs 16
| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| CV outputs | range | 0 to 4 octaves | — | 238 |
| QUANT octave range | selectable range | 1 to 4 octaves | — | 238 |
| clock/MOD inputs | min pulse width | ≥ 2.5 ms | — | 238 |
| clock/MOD inputs | min amplitude | ≥ 2.5 V | — | 238 |
| module | STATEs | 64 states | — | 238 |
| module | banks | 4 banks of 16 | — | 238 |
| channel | locations | 16 locations | — | 238 |
| Snake | patterns | 16 patterns | — | 238 |
| STORE | duration | 8 to 10 s | — | 238 |
| calibration | duration | 2 to 3 min | — | 238 |
| Select Bus | baud rate | 31250 bps | — | 238 |
| Select Bus | modules per bus board | ≤ 20 modules | — | 238 |
| module | power +12V | 235 mA | — | 238 |
| module | power -12V | 0 mA | — | 238 |
| module | width | 34 HP | — | 238 |
| module | max depth | 32 mm | — | 239 |
Properties 11
| Subject | Property | Value | Source |
|---|---|---|---|
| CV outputs | calibration | factory 1V/oct, user-calibratable | 238 |
| X/Y glide time | basis | clock rate | 238 |
| C glide time | basis | constant | 238 |
| CV inputs | unpatched normal | +5V | 238 |
| C channel | FUN.CV.LOC depth | 1/4 of X/Y | 238 |
| C channel | FUN.CV.ADD / S&H | not affected | 238 |
| C channel | SNAKE page | none | 238 |
| Select Bus | bus line | INT.CV, active low | 238 |
| Z-CV / CV.LOC scaling | type | absolute | 238 |
| Latch / M-Paste | stored | no | 238 |
| MOD clocks (FUN.MOD.CLK) | gate output | always triggers | 238 |
Behavior 41
| Subject | When | Effect | Mode | Source |
|---|---|---|---|---|
| C channel | X-CLK pulse | moves horizontally | — | 238 |
| C channel | Y-CLK pulse | moves vertically | — | 238 |
| Location | ACCESS OFF | skipped by sequence | — | 238 |
| Location | GATE ON | gate output fires | — | 238 |
| Location | GLIDE ON | CV glides to value | — | 238 |
| LATCH page | locations touched | overrides ACCESS and GATE | — | 238 |
| LATCH page | nothing selected | reverts to ACCESS/GATE | — | 238 |
| Latched location | reached | always outputs gate | — | 238 |
| C single-location Latch | set | no gates at clock rate | — | 238 |
| FUN.OP.SLEEP | ON, non-ACCESS location | CV rests one clock | — | 238 |
| FUN.OP.SLEEP | OFF | skips non-ACCESS locations | — | 238 |
| C channel SLEEP | induced by an axis | only that axis wakes | — | 238 |
| FUN.OP.TRIG | ON, Gate+Glide location | gate held (tie) | — | 238 |
| C-G | C TRIG OFF, gate location | combines X/Y clock highs | — | 238 |
| FUN.MOD.RESET | MOD rising edge | reset to nearest Location 1 | — | 238 |
| FUN.MOD.CLK | MOD pulse | extra clock advance | — | 238 |
| FUN.MOD.CLK | CLOCK held high | MOD input masked | — | 238 |
| FUN.MOD.RUNSTP | MOD low | channel stops | — | 238 |
| FUN.MOD.RUNSTP / DIR | both | mutually exclusive | — | 238 |
| FUN.CV.ADD / S&H | both | mutually exclusive | — | 238 |
| FUN.CV.S&H | MOD rising edge | CV sampled and added | — | 238 |
| FUN.CV.S&H | cable removed | holds indefinitely | — | 238 |
| FUN.CV.SNAKE | turned OFF | current pattern remains | — | 238 |
| FUN.CV.LOC | clock arrives | start point increments | — | 238 |
| Quantizer | no octave range selected | unquantized, maximum range | — | 238 |
| QUANT octave range | changed | knob values redistributed | — | 238 |
| Knob | turned | applies when location reached | — | 238 |
| Z-MOD / Z-CV | GL.Z.ON OFF | active only on Select STATE | — | 238 |
| Z-MOD | gate on Select STATE page | next enabled STATE | — | 238 |
| GBL.Z.RESET | ON, State selected | all channels reset | — | 238 |
| Z-MOD | Z.RESET ON, Z.ON OFF | global reset, no State change | — | 238 |
| STORE | in progress | sequencing stops | — | 238 |
| power-up | always | last stored State loaded | — | 238 |
| power-up | first boot view | X ACCESS page | — | 238 |
| Multi-Paste | performed | all States M-Paste disabled | — | 238 |
| Multi-Paste | always | into one Bank at once | — | 238 |
| State | always | at least one enabled | — | 238 |
| GBL.BUS | Lead | transmits State actions | — | 238 |
| GBL.BUS | Follow | matches Select Bus State | — | 238 |
| GBL.BUS | default | Free | — | 238 |
| calibration | not stored afterwards | lost at power-off | — | 238 |
Functions 4
| Function | Basis | Scope | Evidence | Source |
|---|---|---|---|---|
| Step Sequencer | block | patchable | blocks X/Y Snake and C Cartesian channels | 238 |
| Quantizer | block | patchable | block Quantizer: per-channel QUANT page | 238 |
| Random / Sample & Hold CV | mode | patchable | mode FUN.CV.S&H: MOD samples CV | 238 |
| Slew Limiter | control | internal | GLIDE page: per-location glide | 238 |
Power
| +12 V | 235 mA |
|---|---|
| −12 V | 0 mA |
| +5 V | — |
| Width | 34 HP |
| Depth | 32 mm |
Other Step Sequencer modules
Firmware 1
| Version | Released | Notes |
|---|---|---|
| 133 | — | Added gate tie behavior to FUN.OP.TRIG: locations with both Gate and Glide enabled cause the gate output to stay high until a non-Glide-enabled location is reached, enabling variable-length tied notes. Also includes bug fixes.238 |
Sources 2
-
[238]
René Manual (current; the post-Classic three-channel sequencer) ↗manual · primary● verified 2026-05-06
-
[239]
Make Noise René product page ↗product page⚠ verified 2026-05-06 · the manufacturer changed this document since