ladik/c-215
Ladik C-215 AHDSR Envelope ADSR Envelope · Looping / Cycling Envelope
4 HP ADSR envelope and looping / cycling envelope by Ladik: 1 input, 1 output, 8 controls, 2 modes.
Inputs 1
The documents don't state: voltage, threshold, impedance (Gate).
Outputs 1
| Jack | What it does | Range | Connections |
|---|---|---|---|
| Envelope 1012 | envelope output cv | 0 to 10 V, unipolar | from AHDSR envelope selected by 5/10V jumper = set |
The documents don't state: impedance (Envelope).
Controls 8
| Control | What it does | Affects | Positions |
|---|---|---|---|
| Attack 1012 | attack time knob | AHDSR envelope | — |
| Hold 1012 | hold time knob | AHDSR envelope | — |
| Decay 1012 | decay time knob | AHDSR envelope | — |
| Sustain 1012 | sustain level / time knob | AHDSR envelope | In 2 modes
|
| Release 1012 | release time knob | AHDSR envelope | — |
| Retrig jumper 1012 | retrig from zero jumper | AHDSR envelope |
|
| Self-trigger jumper 1012 | self-triggering (looping) jumper | AHDSR envelope |
|
| 5/10V jumper 1012 | envelope output range jumper | Envelope |
|
Blocks 1
| Block | Kind | Types | Inputs | Controls | Outputs | Source |
|---|---|---|---|---|---|---|
| AHDSR envelope | AHDSR envelope generator | Envelope generator | Gate | Attack, Hold, Decay, Sustain, Release | Envelope | 1012 |
Modes 2
| Mode | Kind | Selected by | Selection method | Source |
|---|---|---|---|---|
| normal | trigger mode | Self-trigger jumper = removed | internal jumper | 1012 |
| self-trigger | looping mode | Self-trigger jumper = set | internal jumper | 1012 |
Specs 6
Properties 5
Behavior 7
| Subject | When | Effect | Mode | Source |
|---|---|---|---|---|
| gate | retrig jumper set | attack from zero | — | 1012 |
| retrig from zero | gate during envelope | can cause pop | — | 1012 |
| envelope | self-trigger jumper set | triggers itself, loops | self-trigger | 1012 |
| sustain level | self-trigger mode | fixed at 2/3 | self-trigger | 1012 |
| Sustain knob | self-trigger mode | sets sustain time | self-trigger | 1012 |
| output range | 5/10V jumper removed | 5V envelope | — | 1012 |
| output range | 5/10V jumper set | 10V envelope | — | 1012 |
Functions 2
| Function | Basis | Scope | Evidence | Source |
|---|---|---|---|---|
| ADSR Envelope | block | patchable | block AHDSR envelope generator, Envelope out | 1012 |
| Looping / Cycling Envelope | mode | patchable | mode self-trigger: envelope loops | 1012 |
Power
| +12 V | 20 mA |
|---|---|
| −12 V | — |
| +5 V | 0 mA |
| Width | 4 HP |
| Depth | 45 mm |
Other ADSR Envelope modules
Sources 1
-
[1012]
Ladik C-215 AHDSR Envelope product/manual page ↗product page · primary⚠ verified 2026-05-28 · the manufacturer changed this document since