2hp/clk
2hp Clk Master Clock
2 HP master clock by 2hp: 2 inputs, 1 output, 3 controls.
Inputs 2
| Jack | What it does | Range | Connections |
|---|---|---|---|
| PAUSE 1385 | pause gate input gate, trigger | threshold 2.5 V | → clock generator |
| RATE CV 1385 | rate CV input cv | 0 to 5 V, unipolar | → RATE |
The documents don't state: voltage (PAUSE); scaling (RATE CV); impedance (all inputs).
Outputs 1
| Jack | What it does | Range | Connections |
|---|---|---|---|
| OUT 1385 | clock output clock | 0 to 5 V, unipolar | from clock generator |
The documents don't state: pulse, impedance (OUT).
Controls 3
Blocks 1
| Block | Kind | Types | Inputs | Controls | Outputs | Source |
|---|---|---|---|---|---|---|
| clock generator | voltage controlled clock | Clock generator | RATE CV, PAUSE | RATE, RANGE, PAUSE BUTTON | OUT | 1385 |
Specs 10
| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 2 HP | — | 1385 |
| module | depth | 47 mm | — | 1385 |
| module | depth | 45 mm | — | 1386 |
| module | +12V current | 38 mA | — | 1385 |
| module | -12V current | 7 mA | — | 1385 |
| clock generator | period | 0.034 to 10 s | RANGE slow | 1385 |
| clock generator | period | 0.0085 to 2.44 s | RANGE fast | 1385 |
| OUT | output range | 0 to 5 V | — | 1385 |
| PAUSE | threshold | 2.5 V | — | 1385 |
| RATE CV | input range | 0 to 5 V | — | 1385 |
Properties 4
Behavior 6
Functions 1
| Function | Basis | Scope | Evidence | Source |
|---|---|---|---|---|
| Master Clock | block | patchable | block: voltage controlled clock generator | 1385 |
Power
| +12 V | 38 mA |
|---|---|
| −12 V | 7 mA |
| +5 V | — |
| Width | 2 HP |
| Depth | 47 mm |
Other Master Clock modules
Sources 2
- [1385]