vostok/fuji

Vostok Instruments Fuji LFO · ADSR Envelope

10 HP LFO and ADSR envelope by Vostok Instruments: 6 inputs, 6 outputs, 24 controls, 3 modes.

Vostok Instruments · Fuji manual (PDF) ↗

ADSR Envelope · LFO

Inputs 6

Inputs
JackWhat it doesRangeConnections
GATE 1 1943gate input
gate, trigger
threshold 1.5 V
→ Channel 1, GATE 2
GATE 2 1943gate input
gate, trigger
threshold 1.5 V
normalled from GATE 1
→ Channel 2, GATE 3
GATE 3 1943gate input
gate, trigger
threshold 1.5 V
normalled from GATE 2
→ Channel 3, GATE 4
GATE 4 1943gate input
gate, trigger
threshold 1.5 V
normalled from GATE 3
→ Channel 4, GATE 5
GATE 5 1943gate input
gate, trigger
threshold 1.5 V
normalled from GATE 4
→ Channel 5, GATE 6
GATE 6 1943gate input
gate, trigger
threshold 1.5 V
normalled from GATE 5
→ Channel 6

The documents don't state: voltage, polarity, coupling, impedance (all inputs); normalling (GATE 1).

Outputs 6

Outputs
JackWhat it doesRangeConnections
OUT 1 1943envelope output
cv
0 to 8 V, unipolar
from Channel 1
In 3 modes
  • AD: AD envelope, 0-8V
  • Hold (AHR): AHR envelope, 0-8V
  • LFO: bipolar LFO, +/-8V
OUT 2 1943envelope output
cv
0 to 8 V, unipolar
from Channel 2
In 3 modes
  • AD: AD envelope, 0-8V
  • Hold (AHR): AHR envelope, 0-8V
  • LFO: bipolar LFO, +/-8V
OUT 3 1943envelope output
cv
0 to 8 V, unipolar
from Channel 3
In 3 modes
  • AD: AD envelope, 0-8V
  • Hold (AHR): AHR envelope, 0-8V
  • LFO: bipolar LFO, +/-8V
OUT 4 1943envelope output
cv
0 to 8 V, unipolar
from Channel 4
In 3 modes
  • AD: AD envelope, 0-8V
  • Hold (AHR): AHR envelope, 0-8V
  • LFO: bipolar LFO, +/-8V
OUT 5 1943envelope output
cv
0 to 8 V, unipolar
from Channel 5
In 3 modes
  • AD: AD envelope, 0-8V
  • Hold (AHR): AHR envelope, 0-8V
  • LFO: bipolar LFO, +/-8V
OUT 6 1943envelope output
cv
0 to 8 V, unipolar
from Channel 6
In 3 modes
  • AD: AD envelope, 0-8V
  • Hold (AHR): AHR envelope, 0-8V
  • LFO: bipolar LFO, +/-8V

The documents don't state: coupling, audio rate, impedance (all outputs).

Controls 24

Controls
ControlWhat it doesAffectsPositions
ATTACK 1 1943envelope rise time
knob · 1.5 to 1500 ms
Channel 1, OUT 1
In 1 mode
  • LFO: LFO shape and frequency → Channel 1
DECAY 1 1943envelope fall time
knob · 1.5 to 1500 ms
Channel 1, OUT 1
In 1 mode
  • LFO: LFO shape and frequency → Channel 1
HOLD 1 1943hold mode (AHR)
switch
Channel 1
  • left: AD mode
  • right: AHR hold mode
LFO 1 1943LFO mode
switch
Channel 1
  • left: envelope mode
  • right: bipolar LFO mode
ATTACK 2 1943envelope rise time
knob · 1.5 to 1500 ms
Channel 2, OUT 2
In 1 mode
  • LFO: LFO shape and frequency → Channel 2
DECAY 2 1943envelope fall time
knob · 1.5 to 1500 ms
Channel 2, OUT 2
In 1 mode
  • LFO: LFO shape and frequency → Channel 2
HOLD 2 1943hold mode (AHR)
switch
Channel 2
  • left: AD mode
  • right: AHR hold mode
LFO 2 1943LFO mode
switch
Channel 2
  • left: envelope mode
  • right: bipolar LFO mode
ATTACK 3 1943envelope rise time
knob · 1.5 to 1500 ms
Channel 3, OUT 3
In 1 mode
  • LFO: LFO shape and frequency → Channel 3
DECAY 3 1943envelope fall time
knob · 1.5 to 1500 ms
Channel 3, OUT 3
In 1 mode
  • LFO: LFO shape and frequency → Channel 3
HOLD 3 1943hold mode (AHR)
switch
Channel 3
  • left: AD mode
  • right: AHR hold mode
LFO 3 1943LFO mode
switch
Channel 3
  • left: envelope mode
  • right: bipolar LFO mode
ATTACK 4 1943envelope rise time
knob · 1.5 to 1500 ms
Channel 4, OUT 4
In 1 mode
  • LFO: LFO shape and frequency → Channel 4
DECAY 4 1943envelope fall time
knob · 1.5 to 1500 ms
Channel 4, OUT 4
In 1 mode
  • LFO: LFO shape and frequency → Channel 4
HOLD 4 1943hold mode (AHR)
switch
Channel 4
  • left: AD mode
  • right: AHR hold mode
LFO 4 1943LFO mode
switch
Channel 4
  • left: envelope mode
  • right: bipolar LFO mode
ATTACK 5 1943envelope rise time
knob · 1.5 to 1500 ms
Channel 5, OUT 5
In 1 mode
  • LFO: LFO shape and frequency → Channel 5
DECAY 5 1943envelope fall time
knob · 1.5 to 1500 ms
Channel 5, OUT 5
In 1 mode
  • LFO: LFO shape and frequency → Channel 5
HOLD 5 1943hold mode (AHR)
switch
Channel 5
  • left: AD mode
  • right: AHR hold mode
LFO 5 1943LFO mode
switch
Channel 5
  • left: envelope mode
  • right: bipolar LFO mode
ATTACK 6 1943envelope rise time
knob · 1.5 to 1500 ms
Channel 6, OUT 6
In 1 mode
  • LFO: LFO shape and frequency → Channel 6
DECAY 6 1943envelope fall time
knob · 1.5 to 1500 ms
Channel 6, OUT 6
In 1 mode
  • LFO: LFO shape and frequency → Channel 6
HOLD 6 1943hold mode (AHR)
switch
Channel 6
  • left: AD mode
  • right: AHR hold mode
LFO 6 1943LFO mode
switch
Channel 6
  • left: envelope mode
  • right: bipolar LFO mode

Blocks 6

Blocks and their connections
BlockKindTypesInputsControlsOutputsSource
Channel 1slope generatorEnvelope generator, LFOGATE 1ATTACK 1, DECAY 1, HOLD 1, LFO 1OUT 11943
Channel 2slope generatorEnvelope generator, LFOGATE 2ATTACK 2, DECAY 2, HOLD 2, LFO 2OUT 21943
Channel 3slope generatorEnvelope generator, LFOGATE 3ATTACK 3, DECAY 3, HOLD 3, LFO 3OUT 31943
Channel 4slope generatorEnvelope generator, LFOGATE 4ATTACK 4, DECAY 4, HOLD 4, LFO 4OUT 41943
Channel 5slope generatorEnvelope generator, LFOGATE 5ATTACK 5, DECAY 5, HOLD 5, LFO 5OUT 51943
Channel 6slope generatorEnvelope generator, LFOGATE 6ATTACK 6, DECAY 6, HOLD 6, LFO 6OUT 61943

Modes 3

Modes
ModeKindSelected bySelection methodSource
ADtwo-stage AD envelope—HOLD and LFO switches left1943
Hold (AHR)three-stage AHR envelope—HOLD switch right, per channel1943
LFObipolar triangle-like LFO—LFO switch right, per channel1943

Specs 10

Specs
SubjectQuantityValueConditionSource
modulewidth10 HP—1943
moduledepth30 mmincluding power cable1943
module+12V current50 mA—1943
module-12V current50 mA—1943
module+5V current0 mA—1943
Channelattack time1.5 to 1500 ms—1943
Channeldecay time1.5 to 1500 ms—1943
Channelmaximum envelope time3 sAD mode1943
Channelenvelope level8 V—1943
GATE inputthreshold1.5 V—1943

Properties 8

Properties
SubjectPropertyValueSource
Attackcurvelogarithmic1943
Decaycurveexponential1943
envelope circuitimplementationfully analog1944
LFOwaveshapetriangle-like1943
Hold modehold timeequal to gate length1943
Channelcountsix identical1943
ChannelLEDsignal indicator1943
GATE inputschainingdaisy-chained1943

Behavior 7

Behavior rules
SubjectWhenEffectModeSource
Channelgate or trigger at GATEgenerates AD envelopeAD1943
GATE inputunpatchedreceives previous channel's gate—1943
GATE inputcable patchedbreaks daisy chain there—1943
Hold modeHOLD switch rightsustains max for gate lengthHold (AHR)1943
Hold modechannel in LFO modedisabledLFO1943
OUTLFO switch rightbipolar +8/-8VLFO1943
OUTAD or Hold modeunipolar 0-8V—1943

Functions 2

Function tags
FunctionBasisScopeEvidenceSource
ADSR EnvelopeblockpatchableChannel 1-6: AD/AHR envelope generator on OUT1943
LFOmodepatchableLFO mode: bipolar LFO on OUT1943

Power

+12 V50 mA
−12 V50 mA
+5 V0 mA
Width10 HP
Depth30 mm

Other LFO modules

All LFO modules →

Sources 2

  1. [1943]
    Vostok Instruments Fuji manual ↗manual · primary
    ● verified 2026-11-16
  2. [1944]
    Vostok Instruments Fuji product page ↗product page
    ● verified 2026-11-16