doepfer/a-198-2

Doepfer A-198-2 Manual Controller

6 HP manual controller by Doepfer: 2 inputs, 4 outputs, 1 bidirectional jack, 11 controls, 6 modes.

Doepfer · A-198-2 manual (PDF) ↗

Manual Controller

Inputs 2

Inputs
JackWhat it doesRangeConnections
Qnt In 1978quantize on/off
gate
threshold 3 V
→ Quantizer
Manual 1978ribbon manual connector—
→ Manual, Position sensor, Pressure sensor

The documents don't state: voltage, polarity, impedance (Qnt In).

Outputs 4

Outputs
JackWhat it doesRangeConnections
CV 1 Out 1978position CV
cv, pitch
0 to 5 V, unipolar
scaling v oct
from Position sensor, Quantizer
Gate 1 Out 1978position gate
gate
0 to 10 V, unipolar
from Position sensor, Retrigger
CV 2 Out 1978pressure CV
cv
0 to 7 V, unipolar
from Pressure sensor
Gate 2 Out 1978pressure threshold gate
gate
0 to 10 V, unipolar
from Pressure sensor

The documents don't state: pulse, impedance (all outputs); coupling (CV 1 Out, CV 2 Out).

Bidirectional jacks 1

Bidirectional jacks
JackWhat it doesRangeConnections
Rtr In 1978retrigger on/off
gate, midi
threshold 3 V
→ Retrigger
selected by JP7 = jumper removed, cable fitted
In 2 modes
  • default (input): retrigger on/off input → Retrigger
  • Midi Out (output): midi output

The documents don't state: voltage, polarity, impedance (Rtr In).

Controls 11

Controls
ControlWhat it doesAffectsPositions
Quant.1 1978select quantization 1
button
Quantizer, CV 1 Out
  • press: select quantization 1
  • press again: quantization off
In 2 modes
  • Performance: select quantization 1 → Quantizer
  • Config: Sensor: select sensor → Position sensor, Pressure sensor
Quant.2 1978select quantization 2
button
Quantizer, CV 1 Out
  • press: select quantization 2
  • press again: quantization off
In 2 modes
  • Performance: select quantization 2 → Quantizer
  • Config: Range: sensor range → Position sensor, Pressure sensor, CV 1 Out, CV 2 Out
Quant.3 1978select quantization 3
button
Quantizer, CV 1 Out
  • press: select quantization 3
  • press again: quantization off
In 2 modes
  • Performance: select quantization 3 → Quantizer
  • Config: Direction: sensor direction → Position sensor, Pressure sensor
Quant.4 1978select quantization 4
button
Quantizer, CV 1 Out
  • press: select quantization 4
  • press again: quantization off
In 2 modes
  • Performance: select quantization 4 → Quantizer
  • Config: Quantize: program quantizations → Quantizer, Qnt In
Quant.5 1978select quantization 5
button
Quantizer, CV 1 Out
  • press: select quantization 5
  • press again: quantization off
In 2 modes
  • Performance: select quantization 5 → Quantizer
  • Config: Offset: sensor offset → CV 1 Out, CV 2 Out
Quant.6 1978select quantization 6
button
Quantizer, CV 1 Out
  • press: select quantization 6
  • press again: quantization off
In 2 modes
  • Performance: select quantization 6 → Quantizer
  • Config: Threshold: Gate 2 threshold → Gate 2 Out
Quant.7 1978select quantization 7
button
Quantizer, CV 1 Out
  • press: select quantization 7
  • press again: quantization off
In 2 modes
  • Performance: select quantization 7 → Quantizer
  • Config: Retrig: retrigger on/off → Retrigger, Rtr In
Quant.8 1978select quantization 8
button
Quantizer, CV 1 Out
  • press: select quantization 8
  • press again: quantization off
In 2 modes
  • Performance: select quantization 8 → Quantizer
  • Config: Store: store settings
Quant.9 1978select quantization 9
button
Quantizer, CV 1 Out
  • press: select quantization 9
  • press again: quantization off
In 2 modes
  • Performance: select quantization 9 → Quantizer
  • Config: Midi: midi channel → Midi conversion
P1 1978CV1 scale trimmer
other
CV 1 Out—
JP7 1978Rtr socket midi config
jumper
Rtr In, Midi conversion
  • fitted: Rtr retrigger input
  • removed, cabled to JP6: Rtr becomes Midi Out

Blocks 6

Blocks and their connections
BlockKindTypesInputsControlsOutputsSource
Manualribbon controller manualManual controllerManual——1978
Position sensorposition sensorManual controllerManualQuant.1, Quant.2, Quant.3, Quant.5CV 1 Out, Gate 1 Out1978
Pressure sensorpressure sensorManual controllerManualQuant.1, Quant.2, Quant.3, Quant.5, Quant.6CV 2 Out, Gate 2 Out1978
QuantizerCV1 quantizationQuantizerQnt InQuant.1, Quant.2, Quant.3, Quant.4, Quant.5, Quant.6, Quant.7, Quant.8, Quant.9CV 1 Out1978
RetriggerGate 1 retrigger—Rtr InQuant.7Gate 1 Out1978
Midi conversionsensor-to-midi conversion——Quant.9, JP7Rtr In1978

Modes 6

Modes
ModeKindSelected bySelection methodSource
Performanceoperation modeQuant.8 + Quant.9 = simultaneousQuant.8 + Quant.9 together1978
Configoperation modeQuant.8 + Quant.9 = simultaneousQuant.8 + Quant.9 together1978
Quantize onCV1 output—Quant.1-9 button or Qnt In1978
Quantize offCV1 output—press lit button again or Qnt In1978
Retrigger onGate 1—Retrig menu or Rtr In1978
Midi OutRtr socket functionJP7 = removed, cabled to JP6JP7 jumper and cable rework1978

Hidden functions 4

Hidden functions
FunctionTriggerAffectsSource
Config modepress Quant.8 and Quant.9 togetherQuant.1, Quant.2, Quant.3, Quant.4, Quant.5, Quant.6, Quant.7, Quant.8, Quant.91978
Qnt polarityfootswitch on Qnt in Quantize menuQnt In1978
Rtr polarityfootswitch on Rtr in Retrig menuRtr In1978
Program quantizationposition moves cursor, pressure toggles noteQuantizer1978

Specs 21

Specs
SubjectQuantityValueConditionSource
modulewidth6 HP—1978
moduledepth45 mm—1978
module+12V current50 mAmodule + manual1978
module-12V current10 mAmodule + manual1978
CV 1 Outmaximum output voltage1 to 5 V5 steps, from 0V1979
CV 1 Outrange1 to 5 octaves—1978
CV 2 Outoutput range max7 V7 steps1979
Gate outputshigh level10 V—1979
Qnt/Rtr inputslow level≤ 0.5 V—1979
Qnt/Rtr inputshigh level≥ 3 V—1979
Quantizerquantization tables9 tables—1978
Quantizertable size1 octave—1978
Midi conversionreference note36 MIDI note—1978
Midi conversionpressure controller1 CC number—1978
Manualsensor length50 cm—1979
Manuallength600 mm—1979
Manualwidth30 mm—1979
Manualheight18 mmwithout covering cap1979
Manualheight30 mmwith covering cap1979
Manualweight1 kg—1979
modulewidth30 mm—1978

Properties 13

Properties
SubjectPropertyValueSource
moduledisplayblack/white OLED1978
modulebuttons9 illuminated momentary1978
ManualconnectorUSB-type, no USB devices1978
CV 1 Outproportional tofinger position1978
CV 2 Outrises withpressure1978
CV 1 Outmodescontinuous or quantized1978
Offsetapplies toCV1 and CV21978
modulesettings storagenon-volatile via Store1978
panel labelsoutputsinverted1979
Quant buttonsConfig labelsinverted below buttons1978
Midi conversionalternative outputA-180-8 or breakout1979
modulemanual compatibilityA-198 manual usable1979
modulegate in hold modeyes1979

Behavior 18

Behavior rules
SubjectWhenEffectModeSource
Gate 1 Outposition sensor touchedgoes high—1978
Gate 2 Outpressure above thresholdgoes high—1978
Gate 1 Outretrigger on, next quantized CVoff a few ms—1978
Gate 1 Outretrigger off, finger slidesno new gate—1978
Retriggerquantization offnot applicable—1978
Quant buttonslit button pressed againquantization off, continuous CV1—1978
Qnt Involtage appliedtoggles quantize on/off—1978
Rtr Involtage appliedtoggles retrigger on/off—1978
Rtr Inconfigured as Midi Outretrigger input unavailable—1978
Midi conversionquantization activenote on/off sent—1978
Midi conversionquantization off, touchednote 36 then pitch bend—1978
Midi conversionmanual releasednote off 36—1978
Midi conversionpressure appliedCC #1 sent—1978
settingspower off without Storechanges lost—1978
RangePosition sensor selectedvalue is octaves—1978
RangePressure sensor selectedvalue is approx volts—1978
Directionbutton pressedtoggles up/down—1978
Offsetprogrammedadded to sensor CV—1978

Functions 1

Function tags
FunctionBasisScopeEvidenceSource
Manual Controllerblockpatchableribbon manual: position and pressure CV/gates1978

Power

+12 V50 mA
−12 V10 mA
+5 V—
Width6 HP
Depth45 mm

Other Manual Controller modules

All Manual Controller modules →

Sources 2

  1. [1978]
    Doepfer A-198-2 manual ↗manual · primary
    ● verified 2026-11-17
  2. [1979]
    Doepfer A-198-2 product page ↗product page
    ● verified 2026-11-17