doepfer/a-142-5

Doepfer A-142-5 LFO · ADSR Envelope

14 HP LFO and ADSR envelope by Doepfer: 4 inputs, 2 outputs, 6 controls, 2 modes.

Doepfer

ADSR Envelope · Looping / Cycling Envelope · LFO

Inputs 4

Inputs
JackWhat it doesRangeConnections
Trig. 1 2043envelope trigger
trigger
—
→ Unit 1
VCL 1 2043voltage control loop
gate
threshold 3.5 V
→ Unit 1, Loop 1
Trig. 2 2043envelope trigger
trigger
—
normalled from Trig. 1
→ Unit 2
VCL 2 2043voltage control loop
gate
threshold 3.5 V
→ Unit 2, Loop 2

The documents don't state: voltage, polarity, coupling, impedance (all inputs); threshold (Trig. 1, Trig. 2).

Outputs 2

Outputs
JackWhat it doesRangeConnections
Out 1 2043envelope/LFO output
cv
≤ 10 V
from Unit 1
In 2 modes
  • Envelope: envelope output
  • LFO: LFO output
Out 2 2043envelope/LFO output
cv
≤ 10 V
from Unit 2
In 2 modes
  • Envelope: envelope output
  • LFO: LFO output

The documents don't state: polarity, scaling, coupling, audio rate, impedance (all outputs).

Controls 6

Controls
ControlWhat it doesAffectsPositions
Decay 1 2043decay time
knob · 2 to 2000 ms
Unit 1—
Loop 1 2043envelope/LFO select
switch
Unit 1
  • off: envelope generator
  • on: LFO
Attack trimmer 1 2043internal attack time
other · 1 to 15 ms
Unit 1—
Decay 2 2043decay time
knob · 2 to 2000 ms
Unit 2—
Loop 2 2043envelope/LFO select
switch
Unit 2
  • off: envelope generator
  • on: LFO
Attack trimmer 2 2043internal attack time
other · 1 to 15 ms
Unit 2—

Blocks 2

Blocks and their connections
BlockKindTypesInputsControlsOutputsSource
Unit 1envelope generator / LFOEnvelope generator, LFOTrig. 1, VCL 1Decay 1, Loop 1, Attack trimmer 1Out 12043
Unit 2envelope generator / LFOEnvelope generator, LFOTrig. 2, VCL 2Decay 2, Loop 2, Attack trimmer 2Out 22043

Modes 2

Modes
ModeKindSelected bySelection methodSource
Envelopeoperating modeLoop = offLoop switch off, VCL low2043
LFOoperating modeLoop = onLoop switch on or VCL high2043

Specs 11

Specs
SubjectQuantityValueConditionSource
Decaydecay time2 to 2000 ms—2043
Attackattack time1 to 15 msinternal trimmer2043
Attackattack time factory setting3 ms—2043
Decaymodified time range0.2 to 200 mscapacitor modification2043
Decaymodified time range20 to 20000 mscapacitor modification2043
Outpeak voltage10 V—2043
moduleheight1 U—2043
modulewidth14 HP—2043
moduledepth45 mm—2043
module+12V current10 mA—2043
module-12V current10 mA—2043

Properties 5

Properties
SubjectPropertyValueSource
Trig. inputsnormalling1 to 22043
VCL inputsignal typedigital high/low2043
OutindicatorLED2043
moduleformat1U2043
Attack factory settingequivalentTB-303 attack2043

Behavior 13

Behavior rules
SubjectWhenEffectModeSource
Unit 1Loop offtriggered envelope generatorEnvelope2043
Unit 1Loop onruns as LFOLFO2043
VCL 1high, Loop switch offloop turned on—2043
VCL 1below about +3.5Vno loop switching—2043
Unit 1trigger applied in LFO modeenvelope and LFO interfereLFO2043
Unit 1positive trigger edgeenvelope startsEnvelope2043
Unit 2Loop offtriggered envelope generatorEnvelope2043
Unit 2Loop onruns as LFOLFO2043
VCL 2high, Loop switch offloop turned on—2043
VCL 2below about +3.5Vno loop switching—2043
Unit 2trigger applied in LFO modeenvelope and LFO interfereLFO2043
Unit 2positive trigger edgeenvelope startsEnvelope2043
Trig. 2unpatchednormalled from Trig. 1—2043

Functions 3

Function tags
FunctionBasisScopeEvidenceSource
ADSR EnvelopeblockpatchableUnit 1/2: AD envelope on Out2043
Looping / Cycling EnvelopecontrolpatchableLoop switch: envelope loops as LFO2043
LFOmodepatchableLoop on: unit works as LFO2043

Power

+12 V10 mA
−12 V10 mA
+5 V—
Width14 HP
Depth45 mm