vpme/zeroscope
VPME Zeroscope
6 HP Eurorack module by VPME: 3 inputs, 3 outputs, 7 controls, 8 modes.
Inputs 3
| Jack | What it does | Range | Connections |
|---|---|---|---|
| 1 1947 | CH1 input cv, audio | -10 to 10 V coupling dc | → Oscilloscope, Frequency meter, 1 thru In 2 modes
|
| 2 1947 | CH2 input cv, audio | -10 to 10 V coupling dc | → Oscilloscope, Frequency meter, 2 thru In 3 modes
|
| T 1947 | EXT trigger input trigger, audio | -10 to 10 V threshold 1 V coupling dc | → Oscilloscope, Frequency meter, T thru In 3 modes
|
The documents don't state: audio rate, impedance (all inputs).
Outputs 3
| Jack | What it does | Range | Connections |
|---|---|---|---|
| 1 thru 1947 | 1 input thru cv, audio | — | from 1 |
| 2 thru 1947 | 2 input thru cv, audio | — | from 2 |
| T thru 1947 | T input thru trigger, audio | — | from T |
The documents don't state: voltage, polarity, coupling, audio rate, impedance (all outputs).
Controls 7
| Control | What it does | Affects | Positions |
|---|---|---|---|
| upper knob 1947 | timebase knob · 0.00001 to 10 s/div | Oscilloscope | In 3 modes
|
| lower knob 1947 | scope gain knob · 0.5 to 10 V/div | Oscilloscope | In 2 modes
|
| SCOPE MODE 1947 | display mode menu setting | Oscilloscope, Frequency meter |
|
| TRIGGER MODE 1947 | trigger source/edge menu setting | Oscilloscope |
|
| TRIGGER LEVEL 1947 | trigger level menu setting | Oscilloscope | — |
| CH1/2 OFFSET 1947 | channel offset menu setting | Oscilloscope | — |
| GRID 1947 | grid display menu setting | Oscilloscope | — |
Blocks 3
| Block | Kind | Types | Inputs | Controls | Outputs | Source |
|---|---|---|---|---|---|---|
| Oscilloscope | 2-channel oscilloscope | — | 1, 2, T | upper knob, lower knob, SCOPE MODE, TRIGGER MODE, TRIGGER LEVEL, CH1/2 OFFSET, GRID | — | 1947 |
| Frequency meter | frequency measurement and tuner | — | T, 1, 2 | upper knob, lower knob | — | 1947 |
| OLED display | display | — | — | — | — | 1947 |
Modes 8
| Mode | Kind | Selected by | Selection method | Source |
|---|---|---|---|---|
| SINGLE | scope mode | — | SCOPE MODE setting | 1947 |
| DUAL | scope mode | — | SCOPE MODE setting | 1947 |
| X-Y | scope mode | — | SCOPE MODE setting | 1947 |
| FREQ | frequency meter/tuner | — | SCOPE MODE setting | 1947 |
| FRQ3 | triple frequency meter/tuner | — | SCOPE MODE setting | 1947 |
| SETTINGS | settings menu | — | press upper knob | 1947 |
| HOLD | display freeze | — | press and hold lower button | 1947 |
| firmware update | updater | — | hold lower button at power-on | 1947 |
Specs 11
| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 6 HP | — | 1947 |
| module | +12V current | 30 mA | — | 1947 |
| module | -12V current | 10 mA | — | 1947 |
| module | +5V current | 0 mA | — | 1947 |
| Oscilloscope | timebase | 0.00001 to 10 s/div | — | 1947 |
| Oscilloscope | gain | 0.5 to 10 V/div | — | 1947 |
| Frequency meter | tuner range | -45 to 45 cent | — | 1947 |
| Frequency meter | tuner reference | 430 to 450 Hz | — | 1947 |
| firmware update | minimum EXT level | 2 Vpp | — | 1947 |
| Oscilloscope | channels | 2 channels | — | 1947 |
| module | power connector | 16 pins | — | 1947 |
Properties 8
| Subject | Property | Value | Source |
|---|---|---|---|
| inputs | coupling | DC coupled | 1947 |
| inputs | thru jacks | through-connected below | 1947 |
| Oscilloscope | anti-aliasing filter | none sophisticated | 1947 |
| Frequency meter | accuracy | not highly accurate | 1947 |
| display | type | OLED | 1947 |
| display | protection | acrylic shield | 1947 |
| firmware | update method | WAV audio file | 1947 |
| Frequency meter | reference drift | with temperature | 1947 |
Behavior 11
| Subject | When | Effect | Mode | Source |
|---|---|---|---|---|
| DUAL mode | timebase 10 us/div | only CH1 shown | — | 1947 |
| display | input above timebase frequency | waveform can be misleading | — | 1947 |
| TRIGGER MODE | Trg off | scope free running | — | 1947 |
| HOLD | single, dual or XY | available | — | 1947 |
| HOLD | either button pressed | leaves HOLD mode | — | 1947 |
| FREQ | signal at EXT | measured above 1V threshold | — | 1947 |
| tuner | line left of note | frequency too low | — | 1947 |
| tuner | line right of note | frequency too high | — | 1947 |
| inputs | above +/-10V | do not apply | — | 1947 |
| firmware update | LED 1 lit | update data received correctly | — | 1947 |
| firmware update | all 4 LEDs lit | update complete | — | 1947 |
Power
| +12 V | 30 mA |
|---|---|
| −12 V | 10 mA |
| +5 V | 0 mA |
| Width | 6 HP |
| Depth | — |
Sources 2
- [1947]