vermona/fourmulator

fourMulator

Vermona

Capabilities 2

Clock Sourceclock-source
Integrated clock generator with TAP tempo button, CLK OUT, CLK IN, and trigger-sequence output; can serve as clock reference or follow external clock.1134
LFOlfo
Four independent LFO modulators with six waveforms each, syncable to each other or an external/internal clock, with CV-controllable frequency or phase.1134

Jacks 20 (10 in / 10 out)

NameSignalVoltageDescription
Inputs (10)
CH1 CVcv-5V to 5VCV input that modulates frequency in free-run mode, phase shift in SYNC mode, or clock division in CLK mode.1134
CH1 RESETtrigger3.5V to 12VImmediately resets the waveform to its start point when a gate or trigger signal is received.1134
CH2 CVcv-5V to 5VCV input that modulates frequency in free-run mode, phase shift in SYNC mode, or clock division in CLK mode.1134
CH2 RESETtrigger3.5V to 12VImmediately resets the waveform to its start point when a gate or trigger signal is received.1134
CH3 CVcv-5V to 5VCV input that modulates frequency in free-run mode, phase shift in SYNC mode, or clock division in CLK mode.1134
CH3 RESETtrigger3.5V to 12VImmediately resets the waveform to its start point when a gate or trigger signal is received.1134
CH4 CVcv-5V to 5VCV input that modulates frequency in free-run mode, phase shift in SYNC mode, or clock division in CLK mode.1134
CH4 RESETtrigger3.5V to 12VImmediately resets the waveform to its start point when a gate or trigger signal is received.1134
CLK INclock3.5V to 12VAccepts an external clock signal, which replaces the internal clock as the reference for modulators set to CLK mode.1134
GLOBAL RESETtrigger3.5V to 12VResets all modulator waveforms to their start points simultaneously; modulators using their individual per-channel RESET inputs are not affected.1134
Outputs (10)
CH1 TRIGGERtrigger≤12VOutputs a 12V, 10 ms trigger pulse at the start of each LFO waveform cycle.1134
CH1 WAVEcv-5V to 5VOutputs the selected LFO waveform for modulation purposes.1134
CH2 TRIGGERtrigger≤12VOutputs a 12V, 10 ms trigger pulse at the start of each LFO waveform cycle.1134
CH2 WAVEcv-5V to 5VOutputs the selected LFO waveform for modulation purposes.1134
CH3 TRIGGERtrigger≤12VOutputs a 12V, 10 ms trigger pulse at the start of each LFO waveform cycle.1134
CH3 WAVEcv-5V to 5VOutputs the selected LFO waveform for modulation purposes.1134
CH4 TRIGGERtrigger≤12VOutputs a 12V, 10 ms trigger pulse at the start of each LFO waveform cycle.1134
CH4 WAVEcv-5V to 5VOutputs the selected LFO waveform for modulation purposes.1134
CLK OUTclock≤12VOutputs the internal clock signal; always active and carries the internal clock tempo regardless of whether CLK IN is patched.1134
TRIG SEQtrigger≤12VOutputs a combined trigger sequence derived from the trigger signals of all synchronized modulators; requires at least one of modulators 2–4 to be in SYNC mode.1134

Parameters 13

NameTypeRangeBehavior
CH1 SPEEDknob0.05Hz – 100Hz1134
CH1 SYNCswitchModulator 1 only offers OFF and CLK positions since it can only be used as a sync reference but cannot be synchronized itself.1134
CH1 WAVEknobSelects one of six waveforms for the modulator: ascending sawtooth, descending sawtooth, square, triangle, sine, or random (sample & hold).1134
CH2 SPEEDknob0.05Hz – 100HzIn free-run mode sets the modulator's frequency. When synced to a neighbor, acts as phase offset control (0°–180°). When set to CLK mode, selects clock division among eight options.1134
CH2 SYNCswitchThree positions: OFF (free-run at SPEED setting), SYNC (synchronized to left neighbor's frequency with SPEED acting as phase offset 0°–180°), CLK (synced to internal or external clock with SPEED selecting one of eight clock divisions).1134
CH2 WAVEknobSelects one of six waveforms for the modulator: ascending sawtooth, descending sawtooth, square, triangle, sine, or random (sample & hold).1134
CH3 SPEEDknob0.05Hz – 100HzIn free-run mode sets the modulator's frequency. When synced to a neighbor, acts as phase offset control (0°–180°). When set to CLK mode, selects clock division among eight options.1134
CH3 SYNCswitchThree positions: OFF (free-run at SPEED setting), SYNC (synchronized to left neighbor's frequency with SPEED acting as phase offset 0°–180°), CLK (synced to internal or external clock with SPEED selecting one of eight clock divisions).1134
CH3 WAVEknobSelects one of six waveforms for the modulator: ascending sawtooth, descending sawtooth, square, triangle, sine, or random (sample & hold).1134
CH4 SPEEDknob0.05Hz – 100Hz1134
CH4 SYNCswitchThree positions: OFF (free-run at SPEED setting), SYNC (synchronized to left neighbor's frequency with SPEED acting as phase offset 0°–180°), CLK (synced to internal or external clock with SPEED selecting one of eight clock divisions).1134
CH4 WAVEknobSelects one of six waveforms for the modulator: ascending sawtooth, descending sawtooth, square, triangle, sine, or random (sample & hold).1134
TAPbuttonSets the internal clock tempo by tapping; a new tempo takes effect after four taps in a constant rhythm.1134

Firmware history 0 versions

No firmware history recorded.

References 2

  1. [1134]
    Vermona fourMulator User Manual (EN)manual
    verified 2026-06-04
  2. [1135]
    Vermona fourMulator product pageproduct_page
    verified 2026-06-04