mutable-instruments/stages

Stages

Mutable Instruments

Segment generator with flexible input/output layout. Each of 6 segments can be independently configured as ramp, hold, or step, and grouped via gate jack detection to form complex multi-segment envelopes, LFOs, step sequences, and more.514

Capabilities 5

Envelope Generatorenvelope-generator
Up to 6 segments can be combined into complex multi-stage envelopes (ADSR, AHDSR, AD, AR, etc.) based on which GATE inputs are patched. Multiple independent envelopes can coexist in one module.514
Function Generatorfunction-generator
Segment generator whose ramp/hold/step segments combine into complex multi-segment functions - envelopes, LFOs, or sequences.514
LFOlfo
A looping ramp segment acts as an LFO with selectable waveforms (variable slope saw/triangle, sine, variable slope trapezoid). Can be tempo-synced when a GATE signal is patched.514
Sample and Holdsample-and-hold
A single step segment with a patched GATE input acts as a sample-and-hold, recording the voltage set by slider and CV input at each rising edge of the GATE.514
Step Sequencerstep-sequencer
Step segments form the building block of step sequences, with adjustable glide between steps. Up to 6-step sequences are possible within one module.514

Jacks 18 — 12 in / 6 out

NameSignalVoltageDescription
Inputs (12)
GATE 1gate514
GATE 2gate514
GATE 3gate514
GATE 4gate514
GATE 5gate514
GATE 6gate514
TIME/LEVEL CV 1cv514
TIME/LEVEL CV 2cv514
TIME/LEVEL CV 3cv514
TIME/LEVEL CV 4cv514
TIME/LEVEL CV 5cv514
TIME/LEVEL CV 6cv514
Outputs (6)
OUT 1cv0V to 8V514
OUT 2cv0V to 8V514
OUT 3cv0V to 8V514
OUT 4cv0V to 8V514
OUT 5cv0V to 8V514
OUT 6cv0V to 8V514

Parameters 18

NameTypeRangeBehavior
Shape 1knobControls the curve shape of a ramp segment from accelerating through uniform to decelerating. Also controls glide amount for step segments and pulse duration for hold segments.514
Shape 2knobControls the curve shape of a ramp segment from accelerating through uniform to decelerating. Also controls glide amount for step segments and pulse duration for hold segments.514
Shape 3knobControls the curve shape of a ramp segment from accelerating through uniform to decelerating. Also controls glide amount for step segments and pulse duration for hold segments.514
Shape 4knobControls the curve shape of a ramp segment from accelerating through uniform to decelerating. Also controls glide amount for step segments and pulse duration for hold segments.514
Shape 5knobControls the curve shape of a ramp segment from accelerating through uniform to decelerating. Also controls glide amount for step segments and pulse duration for hold segments.514
Shape 6knobControls the curve shape of a ramp segment from accelerating through uniform to decelerating. Also controls glide amount for step segments and pulse duration for hold segments.514
TIME/LEVEL Slider 1fader1ms – 16000msSets the time (for ramp segments) or voltage level (for hold/step segments) of segment 1. CV input [1] is summed with slider position.514
TIME/LEVEL Slider 2fader1ms – 16000msSets the time (for ramp segments) or voltage level (for hold/step segments) of segment 2. CV input [1] is summed with slider position.514
TIME/LEVEL Slider 3fader1ms – 16000msSets the time (for ramp segments) or voltage level (for hold/step segments) of segment 3. CV input [1] is summed with slider position.514
TIME/LEVEL Slider 4fader1ms – 16000msSets the time (for ramp segments) or voltage level (for hold/step segments) of segment 4. CV input [1] is summed with slider position.514
TIME/LEVEL Slider 5fader1ms – 16000msSets the time (for ramp segments) or voltage level (for hold/step segments) of segment 5. CV input [1] is summed with slider position.514
TIME/LEVEL Slider 6fader1ms – 16000msSets the time (for ramp segments) or voltage level (for hold/step segments) of segment 6. CV input [1] is summed with slider position.514
Type Button 1buttonCycles through segment types (ramp, hold, step) for segment 1. Hold for 1 second to toggle looping. Simultaneously press with another segment's button to set a loop range.514
Type Button 2buttonCycles through segment types (ramp, hold, step) for segment 2. Hold for 1 second to toggle looping. Simultaneously press with another segment's button to set a loop range.514
Type Button 3buttonCycles through segment types (ramp, hold, step) for segment 3. Hold for 1 second to toggle looping. Simultaneously press with another segment's button to set a loop range.514
Type Button 4buttonCycles through segment types (ramp, hold, step) for segment 4. Hold for 1 second to toggle looping. Simultaneously press with another segment's button to set a loop range.514
Type Button 5buttonCycles through segment types (ramp, hold, step) for segment 5. Hold for 1 second to toggle looping. Simultaneously press with another segment's button to set a loop range.514
Type Button 6buttonCycles through segment types (ramp, hold, step) for segment 6. Hold for 1 second to toggle looping. Simultaneously press with another segment's button to set a loop range.514

Firmware history 0 versions

No firmware history recorded.

References 2

  1. [514]
    Stages Manual (full)manual
    verified 2026-05-19
  2. [515]
    Mutable Instruments Stages product pageproduct_page
    verified 2026-05-19