joranalogue/step-8

Step 8

Joranalogue Audio Design

Sequential tracking/sampling register: an analogue 1-to-8 signal switch feeding eight high-stability track/sample-and-hold stages, each with its own attenuation slider, analogue output, and gate output. Can be configured as a sequencer, sequential switch, counter, analogue shift register, or addressed voltage source.657

Capabilities 5

Analogue Shift Registeranalogue-shift-register
In shift mode, each step event shifts all stage voltages to their right-hand neighbour; supports rotating shift register configurations.657
Sequencersequencer
Built-in 8-step counter with scan output provides sequencer functionality; individual stage sliders set voltage levels.657
Sequential Switchsequential-switch
Analogue 1-to-8 signal switch with 8 track/sample-and-hold stages; solo mode mutes inactive outputs.657
Signal Switchsignal-switch
657
Track-and-Hold / Sample-and-Holdtrack-and-hold
Each stage holds its voltage with low leakage (minutes-long storage); switchable between track and sample modes.657

Jacks 8 (6 in / 2 out)

NameSignalVoltageDescription
Inputs (6)
Pause Inputgate—While high, step triggers no longer advance the register. In sample mode, the selected stage output is still updated, allowing independent stepping and sampling.657
Reset Inputtrigger—Rising edge returns the register to the stage determined by the Stage Input voltage. In shift mode, all data shifts to align with the newly selected stage. In sample mode, automatically triggers a new sample unless a cable is plugged into the step input.657
Reverse Inputgate—While high, causes the step direction to reverse from right-to-left rather than left-to-right.657
Signal Inputmixed—The main analogue signal input routed to the 1-to-8 switch. In cycle mode it is switched to each stage in turn; in shift mode it is always passed to the leftmost stage. Suitable for audio and CV.657
Stage Inputcv—Analogue CV input to directly address the register to a specific stage. Also determines the reset stage when the reset input receives a trigger.657
Step Inputtrigger≥2VRising edge advances the register by one step. In sample mode also causes a sample to be taken. By plugging a cable in, the automatic sampling on reset is overridden.657
Outputs (2)
Scan Outputmixed—Always outputs the voltage of the currently active stage. Used for sequencer, addressed voltage source, or waveshaper applications.657
Step Outputtrigger≤5VGenerates a 50 µs +5 V trigger pulse on every stage change. Can be used to synchronise other modules with no latency.657

Parameters 4

NameTypeRangeBehavior
CYCLE/SHIFT Switchswitch—In cycle mode, the input signal is passed to each output stage in turn and held when not selected. In shift mode, the input is always passed to the leftmost stage and each stage shifts its voltage to its right-hand neighbour on a step event.657
SOLO/ALL Switchswitch—In solo mode, only the selected analogue output is active; all others are muted at 0 V. In all mode, inactive stages continue to hold their voltages and all outputs remain active.657
Step Buttonbutton—Advances the register by one step. In sample mode also triggers a sample of the input voltage.657
TRACK/SAMPLE Switchswitch—In track mode, the selected stage output follows the input at all times. In sample mode, the input voltage is sampled once the stage becomes active and held constant thereafter.657

Firmware history 0 versions

No firmware history recorded.

References 2

  1. [657]
    Joranalogue Step 8 User Manualmanual
    ● verified 2026-05-21
  2. [658]
    Joranalogue Step 8 product pageproduct_page
    ● verified 2026-05-21