joranalogue/test-3

Joranalogue Audio Design Test 3

8 HP Eurorack module by Joranalogue Audio Design: 2 controls, 3 modes.

Joranalogue Audio Design · joranalogue Test 3 manual (PDF) ↗

Inputs and outputs 0

The record lists no jacks.

Controls 2

Controls
ControlWhat it doesAffectsPositions
RAIL 1280cycle power rails
button
meter, rail LEDs—
MODE 1280cycle measurement modes
button
meter, mode LEDs—

Blocks 2

Blocks and their connections
BlockKindTypesInputsControlsOutputsSource
meterV/mA meterPower / case utility—RAIL, MODELED display1280
METER OUTPUT headerpower output headerPower / case utility———1280

Modes 3

Modes
ModeKindSelected bySelection methodSource
Vmeasurement modeMODE = Vpress MODE to cycle1280
mAmeasurement modeMODE = mApress MODE to cycle1280
mA peakmeasurement modeMODE = PEAKpress MODE to cycle1280

Hidden functions 2

Hidden functions
FunctionTriggerAffectsSource
reset peak valueshold MODE, releasemA peak1280
cancel peak resethold MODE, press RAILmA peak1280

Specs 19

Specs
SubjectQuantityValueConditionSource
modulewidth8 HP—1280
moduledepth28 mmincluding power cable1280
module+12V current35 mA—1280
module+5V current≤ 1 mAif rail available1280
module-12V current≤ 1 mAif rail available1280
V measurementresolution20 mV—1280
V measurementmaximum20 V—1280
V measurementaccuracy5 %—1280
V measurementupdate rate10 Hz—1280
mA measurementresolution1 mA—1280
mA measurementmaximum1 Aper rail1280
mA measurementaccuracy5 %—1280
mA measurementupdate rate10 Hz—1280
mA peakupdate rate100 Hzall rails simultaneously1280
+12 railminimum operating voltage7 V—1280
moduleouter dimensions depth24 mmmodule1280
circuit boardouter dimensions depth11.5 mm—1280
modulemass60 gwith front panel1280
railsnominal voltage tolerance10 %—1280

Properties 9

Properties
SubjectPropertyValueSource
meterrails measured+5, +12, −121280
mA peakbackground updateall rails1280
own current drawadded to +12 mAno1280
METER OUTPUTreverse voltage protectionyes1280
METER OUTPUToverload protectionno1280
moduleformatDIY kit1280
modulefront paneloptional kit1280
displaytypeLED display1280
modulepower protectionreverse polarity MOSFET1280

Behavior 9

Behavior rules
SubjectWhenEffectModeSource
displaymeasurement above limitdisplay blinks (overload)—1280
mA peak LEDnew peak on any railflashes briefly—1280
mA peak LEDin peak modestays litmA peak1280
MODE buttonheld downmA peak, display blinks—1280
mA peak valuesMODE released after holdreset to 0—1280
peak resetRAIL pressed during holdcancelled—1280
mA peaknew maximum reachedstored as peakmA1280
module+12 rail below 7 Vdoes not function—1280
rail LEDsrail selectedthat LED lights—1280

Power

+12 V35 mA
−12 V1 mA
+5 V1 mA
Width8 HP
Depth28 mm

Sources 2

  1. [1280]
    joranalogue Test 3 manual ↗manual · primary
    ● verified 2026-11-16
  2. [1281]
    joranalogue Test 3 product page ↗product page
    ● verified 2026-11-16