intellijel/zeroscope-1u

Intellijel Zeroscope 1U

16 HP Eurorack module by Intellijel: 2 inputs, 2 outputs, 13 controls, 6 modes.

Intellijel · Zeroscope 1U manual (PDF) ↗

Inputs 2

Inputs
JackWhat it doesRangeConnections
CH 1 input 1322CH 1 scope input
audio, cv
-10 to 10 V, bipolar
coupling dc
→ oscilloscope, tuner, CH 1 output
CH 2 input 1322CH 2 scope input
audio, cv
-10 to 10 V, bipolar
coupling dc
→ oscilloscope, tuner, CH 2 output

The documents don't state: scaling, audio rate, impedance (all inputs).

Outputs 2

Outputs
JackWhat it doesRangeConnections
CH 1 output 1322CH 1 thru
audio, cv
—
from CH 1 input
CH 2 output 1322CH 2 thru
audio, cv
—
from CH 2 input

The documents don't state: voltage, polarity, scaling, coupling, audio rate, impedance (all outputs).

Controls 13

Controls
ControlWhat it doesAffectsPositions
Encoder 1322push-function encoder
knob
oscilloscope, tuner—
CH 1 1322CH 1 volts/division
menu setting · 0.5 to 10 V/div
oscilloscope—
CH 2 1322CH 2 volts/division
menu setting · 0.5 to 10 V/div
oscilloscope—
T 1322time base
menu setting · 0.00001 to 10 s/div
oscilloscope—
SCOPE type 1322display type
menu setting
oscilloscope, tuner
  • Scope: time vs voltage
  • X-Y: CH 1 X, CH 2 Y
  • Tune: tuning display
TRIGGER Source 1322trigger source
menu setting
oscilloscope
  • Trg off: untriggered
  • Trg 1 rising: CH 1 rising edge
  • Trg 1 falling: CH 1 falling edge
  • Trg 2 rising: CH 2 rising edge
  • Trg 2 falling: CH 2 falling edge
TRIGGER DETECTION LEVEL 1322trigger threshold
menu setting · -10 to 10 V · bipolar
oscilloscope—
CH 1 offset 1322CH 1 display offset
menu setting · -10 to 10 V · bipolar
oscilloscope—
CH 2 offset 1322CH 2 display offset
menu setting · -10 to 10 V · bipolar
oscilloscope—
GRID display 1322background grid
menu setting
oscilloscope
  • grd: on: grid on
  • grd: --: grid off
ref 1322tuner reference pitch
menu setting
tuner—
avg 1322averaging time
menu setting
tuner
  • slow: least sensitive
  • norm: middle
  • fast: most sensitive
SCREEN SAVER 1322display off delay
menu setting
oscilloscope, tuner
  • 1 min: 1 min
  • 2 min: 2 min
  • 5 min: 5 min
  • 10 min: 10 min
  • 30 min: 30 min
  • 1 hour: 1 hour
  • 2 hour: 2 hour
  • never: never off

Blocks 2

Blocks and their connections
BlockKindTypesInputsControlsOutputsSource
oscilloscopedual channel oscilloscope—CH 1 input, CH 2 inputEncoder—1322
tunerfrequency meter and tuner—CH 1 input, CH 2 inputEncoder—1322

Modes 6

Modes
ModeKindSelected bySelection methodSource
Scopetime/voltage displaySCOPE type = Scope—1322
X-YX-Y displaySCOPE type = X-Y—1322
Tunetuning displaySCOPE type = Tune—1322
Hz DisplayTune sub-display—press encoder in Tune1322
Note Name DisplayTune sub-display—press encoder in Tune1322
Advanced Settingssettings menu—long-press encoder1322

Hidden functions 6

Hidden functions
FunctionTriggerAffectsSource
Advanced Settings menulong-press encoder >1 sSCOPE type, TRIGGER Source, TRIGGER DETECTION LEVEL, CH 1 offset, CH 2 offset, GRID display1322
edit valuepush-turn encoderSCOPE type, TRIGGER Source, TRIGGER DETECTION LEVEL, CH 1 offset, CH 2 offset, GRID display1322
cycle CH 1/CH 2/Tpress encoderCH 1, CH 2, T1322
Hz/Note Name togglepress encoder in Tunetuner1322
screen saver settingTune mode menuSCREEN SAVER1322
wake displaypress or turn encoderoscilloscope1322

Specs 18

Specs
SubjectQuantityValueConditionSource
modulewidth16 HP—1322
moduledepth26 mm—1322
module+12V current8 mA—1322
module-12V current0 mA—1322
CH 1 inputinput range-10 to 10 V—1322
CH 2 inputinput range-10 to 10 V—1322
oscilloscopevertical scale0.5 to 10 V/div—1322
oscilloscopetime base0.00001 to 10 s/div—1322
oscilloscopeintermediate timebase values17 count—1322
TRIGGER DETECTION LEVELrange-10 to 10 V—1322
TRIGGER DETECTION LEVELdefault0 V—1322
CH 1 offsetrange-10 to 10 V—1322
CH 2 offsetrange-10 to 10 V—1322
tunerpitch deviation display-45 to 45 centsNote Name Display1322
tunerminimum input level2 VTune mode1322
Encoderlong-press time≥ 1 s—1322
Tune mode indicatortimeout5 s—1322
SCREEN SAVERdelay1 to 120 min—1322

Properties 6

Properties
SubjectPropertyValueSource
CH inputscouplingDC1322
oscilloscopeanti-aliasing filtersimple1322
tunerchannelsCH 1, CH 21322
Note Name Displayin tune indicatorbox around note1322
firmwareupdate methodUSB1322
designadapted fromVPME.DE Zeroscope 3U1323

Behavior 12

Behavior rules
SubjectWhenEffectModeSource
CH 1 inputpatchedpasses to CH 1 output—1322
CH 2 inputpatchedpasses to CH 2 output—1322
oscilloscopeT at 10 µs/divonly CH 1 displayed—1322
oscilloscopeinput above timebase frequencymay show misleading waveform—1322
tunerinput below +2Vpitch detector failsTune1322
TRIGGER DETECTION LEVELbeyond waveform voltage limitsT? icon shown—1322
oscilloscopeTrg offscope untriggered—1322
Encoderturn in Hz Displayedits avgTune1322
Encoderturn in Note Name Displayedits refTune1322
Note Name Displayline right of notenote sharpTune1322
Note Name Displayline left of notenote flatTune1322
SCREEN SAVERdelay elapseddisplay turns off—1322

Power

+12 V8 mA
−12 V0 mA
+5 V—
Width16 HP
Depth26 mm

Sources 2

  1. [1322]
    intellijel Zeroscope 1U manual ↗manual · primary
    ● verified 2026-11-16
  2. [1323]
    intellijel Zeroscope 1U product page ↗product page
    ● verified 2026-11-16