# Zeroscope (VPME)

Canonical page: https://eurorackref.com/vpme/zeroscope/

- id: `vpme/zeroscope`
- width: 6 HP; depth: unknown mm
- power: +12 V 30 mA, −12 V 10 mA, +5 V 0 mA
- status: current

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| 1 | cv, audio | CH1 input | -10 to 10 V | unknown | — | 1947 |
| 2 | cv, audio | CH2 input | -10 to 10 V | unknown | — | 1947 |
| T | trigger, audio | EXT trigger input | -10 to 10 V | unknown | — | 1947 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| 1 thru | cv, audio | 1 input thru | not stated | not stated | 1 | 1947 |
| 2 thru | cv, audio | 2 input thru | not stated | not stated | 2 | 1947 |
| T thru | trigger, audio | T input thru | not stated | not stated | T | 1947 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| upper knob | knob | timebase | 0.00001 to 10 s/div | Oscilloscope | 1947 |
| lower knob | knob | scope gain | 0.5 to 10 V/div | Oscilloscope | 1947 |
| SCOPE MODE | menu_setting | display mode | — | Oscilloscope, Frequency meter | 1947 |
| TRIGGER MODE | menu_setting | trigger source/edge | — | Oscilloscope | 1947 |
| TRIGGER LEVEL | menu_setting | trigger level | — | Oscilloscope | 1947 |
| CH1/2 OFFSET | menu_setting | channel offset | — | Oscilloscope | 1947 |
| GRID | menu_setting | grid display | — | Oscilloscope | 1947 |

## Modes

- SINGLE [1947]
- DUAL [1947]
- X-Y [1947]
- FREQ [1947]
- FRQ3 [1947]
- SETTINGS [1947]
- HOLD [1947]
- firmware update [1947]

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 6 HP | — | 1947 |
| module | +12V current | 30 mA | — | 1947 |
| module | -12V current | 10 mA | — | 1947 |
| module | +5V current | 0 mA | — | 1947 |
| Oscilloscope | timebase | 0.00001 to 10 s/div | — | 1947 |
| Oscilloscope | gain | 0.5 to 10 V/div | — | 1947 |
| Frequency meter | tuner range | -45 to 45 cent | — | 1947 |
| Frequency meter | tuner reference | 430 to 450 Hz | — | 1947 |
| firmware update | minimum EXT level | 2 Vpp | — | 1947 |
| Oscilloscope | channels | 2 channels | — | 1947 |
| module | power connector | 16 pins | — | 1947 |

## Behavior

- DUAL mode: when timebase 10 us/div → only CH1 shown [1947]
- display: when input above timebase frequency → waveform can be misleading [1947]
- TRIGGER MODE: when Trg off → scope free running [1947]
- HOLD: when single, dual or XY → available [1947]
- HOLD: when either button pressed → leaves HOLD mode [1947]
- FREQ: when signal at EXT → measured above 1V threshold [1947]
- tuner: when line left of note → frequency too low [1947]
- tuner: when line right of note → frequency too high [1947]
- inputs: when above +/-10V → do not apply [1947]
- firmware update: when LED 1 lit → update data received correctly [1947]
- firmware update: when all 4 LEDs lit → update complete [1947]

## Sources

- [1947] VPME Zeroscope manual (manual): https://drive.google.com/uc?export=download&id=1CcRXCWsOrPLW8udxyOYGhwAU7z2svnF8
- [1948] VPME Zeroscope product page (product_page): https://vpme.de/zeroscope/

Full record as JSON: https://eurorackref.com/vpme/zeroscope.json