# VU Meters (Tobinski)

Canonical page: https://eurorackref.com/tobinski/vu-meters/

- id: `tobinski/vu-meters`
- width: 8 HP; depth: 51 mm
- power: +12 V 0.03 mA, −12 V 83 mA, +5 V 3 mA
- status: current

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| External input 1 | audio | external monitor input | not stated | unknown | — | 2034 |
| External input 2 | audio | external monitor input | not stated | unknown | — | 2034 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| Source switch 1 | switch | meter source select | — | Meter 1 | 2034 |
| Sensitivity switch 1 | switch | meter sensitivity | — | Meter 1 | 2034 |
| Source switch 2 | switch | meter source select | — | Meter 2 | 2034 |
| Sensitivity switch 2 | switch | meter sensitivity | — | Meter 2 | 2034 |

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 8 HP | — | 2034 |
| module | depth | 51 mm | — | 2034 |
| module | +12V current | 0.03 mA | — | 2034 |
| module | -12V current | 83 mA | — | 2034 |
| module | +5V current | 3 mA | — | 2034 |

## Behavior

- INPUT position: when external input patched → monitors external input [2034]
- INPUT position: when external input unpatched → monitors Dynamics input level [2034]
- OFF position: when selected → needles stop, backlights stay on [2034]

## Sources

- [2034] Tobinski VU Meters product page (product_page): https://www.tobinski-audio.com/modules/vu-meters

Full record as JSON: https://eurorackref.com/tobinski/vu-meters.json