  "id": "tobinski/vu-meters",
  "manufacturer": {
    "id": "tobinski",
    "name": "Tobinski"
  },
  "name": "VU Meters",
  "hp": 8,
  "depth_mm": 51,
  "power": {
    "plus_12": 0.03,
    "minus_12": 83,
    "plus_5": 3
  },
  "production_status": "current",
  "function_tags": [],
  "url": "https://eurorackref.com/tobinski/vu-meters/",
  "record": {
    "blocks": [
      {
        "src": 2034,
        "name": "Meter 1",
        "kind": "VU meter",
        "controls": [
          "Source switch 1",
          "Sensitivity switch 1"
        ],
        "inputs": [
          "External input 1"
        ],
        "outputs": [],
        "types": [
          "power_utility"
        ]
      },
      {
        "src": 2034,
        "name": "Meter 2",
        "kind": "VU meter",
        "controls": [
          "Source switch 2",
          "Sensitivity switch 2"
        ],
        "inputs": [
          "External input 2"
        ],
        "outputs": [],
        "types": [
          "power_utility"
        ]
      }
    ],
    "jacks": [
      {
        "src": 2034,
        "name": "External input 1",
        "direction": "input",
        "signal_types": [
          "audio"
        ],
        "function": "external monitor input",
        "voltage_min": null,
        "voltage_max": null,
        "polarity": null,
        "scaling": null,
        "threshold_v": null,
        "pulse_ms": null,
        "coupling": null,
        "audio_rate": null,
        "impedance_ohms": null,
        "normalled_from": null,
        "attenuated_by": null,
        "feeds": [
          "Meter 1"
        ],
        "sourced_from": [],
        "selected_by": [
          {
            "control": "Source switch 1",
            "position": "INPUT"
          }
        ],
        "per_mode": [],
        "types": [],
        "not_stated": [
          "voltage_min",
          "voltage_max",
          "impedance_ohms"
        ],
        "name_basis": "inferred",
        "label_in_source": true
      },
      {
        "src": 2034,
        "name": "External input 2",
        "direction": "input",
        "signal_types": [
          "audio"
        ],
        "function": "external monitor input",
        "voltage_min": null,
        "voltage_max": null,
        "polarity": null,
        "scaling": null,
        "threshold_v": null,
        "pulse_ms": null,
        "coupling": null,
        "audio_rate": null,
        "impedance_ohms": null,
        "normalled_from": null,
        "attenuated_by": null,
        "feeds": [
          "Meter 2"
        ],
        "sourced_from": [],
        "selected_by": [
          {
            "control": "Source switch 2",
            "position": "INPUT"
          }
        ],
        "per_mode": [],
        "types": [],
        "not_stated": [
          "voltage_min",
          "voltage_max",
          "impedance_ohms"
        ],
        "name_basis": "inferred",
        "label_in_source": true
      }
    ],
    "controls": [
      {
        "src": 2034,
        "name": "Source switch 1",
        "control_type": "switch",
        "function": "meter source select",
        "range_min": null,
        "range_max": null,
        "range_unit": null,
        "bipolar": null,
        "affects": [
          "Meter 1"
        ],
        "positions": [
          {
            "label": "C/E OUT",
            "effect": "monitor C/E output"
          },
          {
            "label": "INPUT",
            "effect": "monitor input level"
          },
          {
            "label": "C/E AMT",
            "effect": "monitor C/E amount"
          }
        ],
        "per_mode": [],
        "name_basis": "described",
        "label_in_source": false
      },
      {
        "src": 2034,
        "name": "Sensitivity switch 1",
        "control_type": "switch",
        "function": "meter sensitivity",
        "range_min": null,
        "range_max": null,
        "range_unit": null,
        "bipolar": null,
        "affects": [
          "Meter 1"
        ],
        "positions": [
          {
            "label": "HI SENS",
            "effect": "high sensitivity"
          },
          {
            "label": "OFF",
            "effect": "needles stop, backlight on"
          },
          {
            "label": "LO SENS",
            "effect": "low sensitivity"
          }
        ],
        "per_mode": [],
        "name_basis": "described",
        "label_in_source": false
      },
      {
        "src": 2034,
        "name": "Source switch 2",
        "control_type": "switch",
        "function": "meter source select",
        "range_min": null,
        "range_max": null,
        "range_unit": null,
        "bipolar": null,
        "affects": [
          "Meter 2"
        ],
        "positions": [
          {
            "label": "C/E OUT",
            "effect": "monitor C/E output"
          },
          {
            "label": "INPUT",
            "effect": "monitor input level"
          },
          {
            "label": "C/E AMT",
            "effect": "monitor C/E amount"
          }
        ],
        "per_mode": [],
        "name_basis": "described",
        "label_in_source": false
      },
      {
        "src": 2034,
        "name": "Sensitivity switch 2",
        "control_type": "switch",
        "function": "meter sensitivity",
        "range_min": null,
        "range_max": null,
        "range_unit": null,
        "bipolar": null,
        "affects": [
          "Meter 2"
        ],
        "positions": [
          {
            "label": "HI SENS",
            "effect": "high sensitivity"
          },
          {
            "label": "OFF",
            "effect": "needles stop, backlight on"
          },
          {
            "label": "LO SENS",
            "effect": "low sensitivity"
          }
        ],
        "per_mode": [],
        "name_basis": "described",
        "label_in_source": false
      }
    ],
    "modes": [],
    "hidden_functions": [],
    "specs": [
      {
        "src": 2034,
        "subject": "module",
        "quantity": "width",
        "min": null,
        "max": null,
        "value": 8,
        "unit": "HP",
        "condition": null
      },
      {
        "src": 2034,
        "subject": "module",
        "quantity": "depth",
        "min": null,
        "max": null,
        "value": 51,
        "unit": "mm",
        "condition": null
      },
      {
        "src": 2034,
        "subject": "module",
        "quantity": "+12V current",
        "min": null,
        "max": null,
        "value": 0.03,
        "unit": "mA",
        "condition": null
      },
      {
        "src": 2034,
        "subject": "module",
        "quantity": "-12V current",
        "min": null,
        "max": null,
        "value": 83,
        "unit": "mA",
        "condition": null
      },
      {
        "src": 2034,
        "subject": "module",
        "quantity": "+5V current",
        "min": null,
        "max": null,
        "value": 3,
        "unit": "mA",
        "condition": null
      }
    ],
    "properties": [
      {
        "src": 2034,
        "subject": "module",
        "property": "companion module",
        "value": "2 x Dynamics"
      },
      {
        "src": 2034,
        "subject": "module",
        "property": "link to Dynamics",
        "value": "2x3 pin ribbon"
      },
      {
        "src": 2034,
        "subject": "meters",
        "property": "backlight",
        "value": "yes"
      },
      {
        "src": 2034,
        "subject": "module",
        "property": "channels",
        "value": "2"
      }
    ],
    "rules": [
      {
        "src": 2034,
        "subject": "INPUT position",
        "when": "external input patched",
        "effect": "monitors external input",
        "mode": null
      },
      {
        "src": 2034,
        "subject": "INPUT position",
        "when": "external input unpatched",
        "effect": "monitors Dynamics input level",
        "mode": null
      },
      {
        "src": 2034,
        "subject": "OFF position",
        "when": "selected",
        "effect": "needles stop, backlights stay on",
        "mode": null
      }
    ],
    "tags": []
  },
  "sources": [
    {
      "id": 2034,
      "source_type": "product_page",
      "format": "html",
      "title": "Tobinski VU Meters product page",
      "canonical_url": "https://www.tobinski-audio.com/modules/vu-meters",
      "url": "https://eurorackref.com/tobinski/vu-meters/#src-2034",
      "last_verified": "2026-11-17",
      "canonical_changed_at": null,
      "primary": true
    }
  ],
  "firmware_versions": [],
  "_meta": {
    "last_verified": "2026-11-17",
    "record_meta": {
      "schema_version": 4,
      "extracted_at": "2026-11-17T21:16:15Z"
    }
  }
}