# Stages (Mutable Instruments)

Canonical page: https://eurorackref.com/mutable-instruments/stages/

- id: `mutable-instruments/stages`
- width: 14 HP; depth: 25 mm
- power: +12 V 80 mA, −12 V 20 mA, +5 V ? mA
- status: current
- functions: ADSR Envelope, Looping / Cycling Envelope, LFO, End-of-Cycle / End-of-Rise Output, Tempo / Clock Sync, Random / Sample & Hold CV, Slew Limiter, Step Sequencer, Gate / Trigger Utility

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| GATE 1 | gate, trigger, clock | gate / group start | unknown | not stated | — | 514 |
| TIME/LEVEL CV 1 | cv | time or level CV | not stated | not stated | — | 514 |
| GATE 2 | gate, trigger, clock | gate / group start | unknown | not stated | — | 514 |
| TIME/LEVEL CV 2 | cv | time or level CV | not stated | not stated | — | 514 |
| GATE 3 | gate, trigger, clock | gate / group start | unknown | not stated | — | 514 |
| TIME/LEVEL CV 3 | cv | time or level CV | not stated | not stated | — | 514 |
| GATE 4 | gate, trigger, clock | gate / group start | unknown | not stated | — | 514 |
| TIME/LEVEL CV 4 | cv | time or level CV | not stated | not stated | — | 514 |
| GATE 5 | gate, trigger, clock | gate / group start | unknown | not stated | — | 514 |
| TIME/LEVEL CV 5 | cv | time or level CV | not stated | not stated | — | 514 |
| GATE 6 | gate, trigger, clock | gate / group start | unknown | not stated | — | 514 |
| TIME/LEVEL CV 6 | cv | time or level CV | not stated | not stated | — | 514 |
| Chain connector | — | daisy-chain link | unknown | unknown | — | 515 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| Output 1 | cv, gate | segment output | -8 to 8 V | bipolar | Segment 1 | 514 |
| Output 2 | cv, gate | segment output | -8 to 8 V | bipolar | Segment 2 | 514 |
| Output 3 | cv, gate | segment output | -8 to 8 V | bipolar | Segment 3 | 514 |
| Output 4 | cv, gate | segment output | -8 to 8 V | bipolar | Segment 4 | 514 |
| Output 5 | cv, gate | segment output | -8 to 8 V | bipolar | Segment 5 | 514 |
| Output 6 | cv, gate | segment output | -8 to 8 V | bipolar | Segment 6 | 514 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| TIME/LEVEL slider 1 | fader | time or level | — | Segment 1 | 514 |
| Potentiometer [A] 1 | knob | curve, glide or duration | — | Segment 1 | 514 |
| Button [B] 1 | button | segment type, loop | — | Segment 1 | 514 |
| TIME/LEVEL slider 2 | fader | time or level | — | Segment 2 | 514 |
| Potentiometer [A] 2 | knob | curve, glide or duration | — | Segment 2 | 514 |
| Button [B] 2 | button | segment type, loop | — | Segment 2 | 514 |
| TIME/LEVEL slider 3 | fader | time or level | — | Segment 3 | 514 |
| Potentiometer [A] 3 | knob | curve, glide or duration | — | Segment 3 | 514 |
| Button [B] 3 | button | segment type, loop | — | Segment 3 | 514 |
| TIME/LEVEL slider 4 | fader | time or level | — | Segment 4 | 514 |
| Potentiometer [A] 4 | knob | curve, glide or duration | — | Segment 4 | 514 |
| Button [B] 4 | button | segment type, loop | — | Segment 4 | 514 |
| TIME/LEVEL slider 5 | fader | time or level | — | Segment 5 | 514 |
| Potentiometer [A] 5 | knob | curve, glide or duration | — | Segment 5 | 514 |
| Button [B] 5 | button | segment type, loop | — | Segment 5 | 514 |
| TIME/LEVEL slider 6 | fader | time or level | — | Segment 6 | 514 |
| Potentiometer [A] 6 | knob | curve, glide or duration | — | Segment 6 | 514 |
| Button [B] 6 | button | segment type, loop | — | Segment 6 | 514 |

## Modes

- RAMP (Button [B] = press) [515]
- HOLD (Button [B] = press) [515]
- STEP (Button [B] = press) [515]
- single-segment loop (Button [B] = hold 1s) [514]
- multi-segment loop [514]
- segment group [514]

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| CV output | voltage range | 0 to 8 V | — | 515 |
| CV output | negative range | -8 to 0 V | HOLD/STEP CV modulated | 515 |
| segment | duration | 0.001 to 16 s | — | 515 |
| STEP/HOLD level | voltage range | 0 to 8 V | — | 514 |
| looping RAMP | clock div/mult | 0.25 to 4 ratio | GATE patched | 514 |
| segment activity | ramp range | 0 to 8 V | — | 514 |
| inputs | impedance | 100000 ohm | — | 515 |
| inputs | bandwidth | 0 to 2000 Hz | — | 515 |
| module | refresh rate | 31250 Hz | — | 515 |
| CV capture | resolution | 16 bit | — | 515 |
| CV generation | resolution | 14 bit | — | 515 |
| CV generation | error | ≤ 2 mV | — | 515 |
| chain | max modules | 6 modules | — | 514 |
| module | width | 14 HP | — | 515 |
| module | depth | 25 mm | — | 515 |
| module | +12V current | 80 mA | — | 514 |
| module | -12V current | 20 mA | — | 514 |

## Behavior

- GATE: when patched → starts new segment group [514]
- unpatched segments: when right of patched GATE → join that group [514]
- group first output: when group active → outputs envelope [514]
- group later outputs: when segment active → 8V-to-0V activity ramp [514]
- segments: when no GATE patched → all independent, free running [514]
- first RAMP: when envelope start → ramps up to 8V [514]
- last RAMP: when envelope end → ramps down to 0V [514]
- RAMP end level: when HOLD/STEP adjacent → set by that level [514]
- RAMP end level: when not set by rules → set by potentiometer [A] [514]
- loop: when GATE high → loop plays [514]
- loop: when GATE goes low → continue after loop end [514]
- loop: when includes last segment → loops forever [514]
- envelope: when reaches STEP segment → waits for next trigger [514]
- loop: when contains STEP segment → cannot escape loop [514]
- loop: when spans different groups → not allowed [514]
- single RAMP: when not looping → decay envelope [514]
- looping single RAMP: when GATE unpatched → free LFO, slider rate [514]
- looping single RAMP: when GATE patched → tempo-synced LFO [514]
- single STEP: when GATE rising edge → sample and hold [514]
- single STEP: when GATE unpatched → tracks with glide [514]
- single HOLD: when GATE patched → pulse generator [514]
- single HOLD: when GATE patched, looping → pulse lasts gate length [514]
- single HOLD: when GATE unpatched → CV delay [514]
- HOLD/STEP output: when CV modulated negative → down to -8V [515]

## Sources

- [514] Stages Manual (full) (manual): https://pichenettes.github.io/mutable-instruments-documentation/modules/stages/manual/
- [515] Mutable Instruments Stages product page (product_page): https://pichenettes.github.io/mutable-instruments-documentation/modules/stages/

Full record as JSON: https://eurorackref.com/mutable-instruments/stages.json