# C-240 VC Envelope (Ladik)

Canonical page: https://eurorackref.com/ladik/c-240/

- id: `ladik/c-240`
- width: 8 HP; depth: 45 mm
- power: +12 V 35 mA, −12 V ? mA, +5 V ? mA
- status: current
- functions: ADSR Envelope

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| GATE | gate | gate input | not stated | unknown | — | 1000 |
| TRIG | trigger | retrigger input | not stated | unknown | — | 1000 |
| Attack CV | cv | attack time CV | not stated | unknown | — | 1000 |
| Decay CV | cv | decay time CV | not stated | unknown | — | 1000 |
| Sustain CV | cv | sustain level CV | not stated | unknown | — | 1000 |
| Release CV | cv | release time CV | not stated | unknown | — | 1000 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| Inverted envelope | cv | inverted envelope output | not stated | unknown | envelope generator | 1000 |
| Envelope | cv | envelope output | 0 to 10 V | unipolar | envelope generator | 1000 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| Attack | knob | attack time | 1 to 12000 ms | envelope generator, Attack CV | 1000 |
| Decay | knob | decay time | 1 to 12000 ms | envelope generator, Decay CV | 1000 |
| Sustain | knob | sustain level | — | envelope generator, Sustain CV | 1000 |
| Release | knob | release time | 1 to 12000 ms | envelope generator, Release CV | 1000 |
| Shape | knob | envelope shape | — | envelope generator | 1000 |
| RETRIG MODE/S-SHAPES | button | retrig mode, S-shapes | — | envelope generator, GATE, TRIG | 1000 |
| output range jumper | jumper | output range | — | Envelope, Inverted envelope | 1000 |
| retrig while gate jumper | jumper | retrigger gating | — | TRIG | 1000 |

## Modes

- normal shapes [1000]
- S-shapes (RETRIG MODE/S-SHAPES = long press) [1000]
- gate actual / trig actual (RETRIG MODE/S-SHAPES = short press) [1000]
- gate actual / trig zero (RETRIG MODE/S-SHAPES = short press) [1000]
- gate zero / trig actual (RETRIG MODE/S-SHAPES = short press) [1000]
- gate zero / trig zero (RETRIG MODE/S-SHAPES = short press) [1000]

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| A, D, R segments | time range | 1 to 12000 ms | max is 'over 12 s' | 1000 |
| segment time | time at 9 o'clock | 10 ms | — | 1000 |
| segment time | time at 12 o'clock | 500 ms | — | 1000 |
| segment time | time at 3 o'clock | 4 s | — | 1000 |
| module | width | 8 HP | — | 1000 |
| module | depth | ≤ 45 mm | — | 1000 |
| module | current draw | 35 mA | — | 1000 |

## Behavior

- retrig mode 1: when gate or trig → retrig from actual level [1000]
- retrig mode 2: when trig arrives → jump to zero, restart [1000]
- retrig mode 2: when gate arrives → retrig from actual level [1000]
- retrig mode 3: when gate arrives → retrig from zero [1000]
- retrig mode 3: when trig arrives → retrig from actual level [1000]
- retrig mode 4: when gate or trig → retrig from zero [1000]
- retrig from zero: when envelope active → can cause click [1000]
- TRIG: when jumper installed, gate off → retrigger ignored [1000]
- TRIG: when jumper removed → retrigger anytime [1000]
- segment knob: when CV patched → becomes CV attenuator [1000]
- output range jumpers: when both headers set → not allowed, set one [1000]
- Shape: when S-shapes mode → S-shape to inverted S (S-shapes) [1000]

## Sources

- [1000] Ladik C-240 VC Envelope product/manual page (product_page): https://ladik.ladik.eu/?page_id=2679

Full record as JSON: https://eurorackref.com/ladik/c-240.json