# Test 3 (Joranalogue Audio Design)

Canonical page: https://eurorackref.com/joranalogue/test-3/

- id: `joranalogue/test-3`
- width: 8 HP; depth: 28 mm
- power: +12 V 35 mA, −12 V 1 mA, +5 V 1 mA
- status: current

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| RAIL | button | cycle power rails | — | meter, rail LEDs | 1280 |
| MODE | button | cycle measurement modes | — | meter, mode LEDs | 1280 |

## Modes

- V (MODE = V) [1280]
- mA (MODE = mA) [1280]
- mA peak (MODE = PEAK) [1280]

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 8 HP | — | 1280 |
| module | depth | 28 mm | including power cable | 1280 |
| module | +12V current | 35 mA | — | 1280 |
| module | +5V current | ≤ 1 mA | if rail available | 1280 |
| module | -12V current | ≤ 1 mA | if rail available | 1280 |
| V measurement | resolution | 20 mV | — | 1280 |
| V measurement | maximum | 20 V | — | 1280 |
| V measurement | accuracy | 5 % | — | 1280 |
| V measurement | update rate | 10 Hz | — | 1280 |
| mA measurement | resolution | 1 mA | — | 1280 |
| mA measurement | maximum | 1 A | per rail | 1280 |
| mA measurement | accuracy | 5 % | — | 1280 |
| mA measurement | update rate | 10 Hz | — | 1280 |
| mA peak | update rate | 100 Hz | all rails simultaneously | 1280 |
| +12 rail | minimum operating voltage | 7 V | — | 1280 |
| module | outer dimensions depth | 24 mm | module | 1280 |
| circuit board | outer dimensions depth | 11.5 mm | — | 1280 |
| module | mass | 60 g | with front panel | 1280 |
| rails | nominal voltage tolerance | 10 % | — | 1280 |

## Behavior

- display: when measurement above limit → display blinks (overload) [1280]
- mA peak LED: when new peak on any rail → flashes briefly [1280]
- mA peak LED: when in peak mode → stays lit (mA peak) [1280]
- MODE button: when held down → mA peak, display blinks [1280]
- mA peak values: when MODE released after hold → reset to 0 [1280]
- peak reset: when RAIL pressed during hold → cancelled [1280]
- mA peak: when new maximum reached → stored as peak (mA) [1280]
- module: when +12 rail below 7 V → does not function [1280]
- rail LEDs: when rail selected → that LED lights [1280]

## Sources

- [1280] joranalogue Test 3 manual (manual): https://joranalogue.com/test-3/manual
- [1281] joranalogue Test 3 product page (product_page): https://joranalogue.com/collections/all/products/test-3

Full record as JSON: https://eurorackref.com/joranalogue/test-3.json