# Switched Mult 1U (Intellijel)

Canonical page: https://eurorackref.com/intellijel/switched-mult-1u/

- id: `intellijel/switched-mult-1u`
- width: 14 HP; depth: 18 mm
- power: +12 V 0 mA, −12 V 0 mA, +5 V 0 mA
- status: current
- functions: Multiple / Buffered Mult

## Bidirectional jacks

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| jack 1 | audio, cv, gate | unbuffered mult jack | not stated | unknown | — | 1269 |
| jack 2 | audio, cv, gate | unbuffered mult jack | not stated | unknown | — | 1269 |
| jack 3 | audio, cv, gate | unbuffered mult jack | not stated | unknown | — | 1269 |
| jack 4 | audio, cv, gate | unbuffered mult jack | not stated | unknown | — | 1269 |
| jack 5 | audio, cv, gate | unbuffered mult jack | not stated | unknown | — | 1269 |
| jack 6 | audio, cv, gate | unbuffered mult jack | not stated | unknown | — | 1269 |
| 3-pin Link connector 1 | audio, cv | X/Y bus link | not stated | unknown | — | 1269 |
| 3-pin Link connector 2 | audio, cv | X/Y bus link | not stated | unknown | — | 1269 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| Bus Switch 1 | switch | jack bus assignment | — | jack 1, X bus, Y bus | 1269 |
| Bus Switch 2 | switch | jack bus assignment | — | jack 2, X bus, Y bus | 1269 |
| Bus Switch 3 | switch | jack bus assignment | — | jack 3, X bus, Y bus | 1269 |
| Bus Switch 4 | switch | jack bus assignment | — | jack 4, X bus, Y bus | 1269 |
| Bus Switch 5 | switch | jack bus assignment | — | jack 5, X bus, Y bus | 1269 |
| Bus Switch 6 | switch | jack bus assignment | — | jack 6, X bus, Y bus | 1269 |

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 14 HP | — | 1269 |
| module | depth | 18 mm | — | 1269 |
| module | +12V current | 0 mA | passive | 1269 |
| module | -12V current | 0 mA | passive | 1269 |
| module | +5V current | 0 mA | passive | 1269 |

## Behavior

- jack: when Bus Switch up → joins X bus [1269]
- jack: when Bus Switch down → joins Y bus [1269]
- jack: when Bus Switch middle → carries no signal [1269]
- signal into jack: when patched → appears on same-bus jacks [1269]
- Link connectors: when linked to Switched Mult → X and Y buses shared [1269]
- Link connector: when linked to XY I/O JP2 → XY I/O X, Y join buses [1269]
- module: when powered → requires no power [1269]

## Sources

- [1269] intellijel Switched Mult 1U manual (manual): https://intellijel.com/downloads/manuals/switched-mult-1u_manual_2021.03.21.pdf
- [1270] intellijel Switched Mult 1U product page (product_page): https://intellijel.com/shop/eurorack/1u/switched-mult-1u/

Full record as JSON: https://eurorackref.com/intellijel/switched-mult-1u.json