# Qx (Intellijel)

Canonical page: https://eurorackref.com/intellijel/qx/

- id: `intellijel/qx`
- width: 4 HP; depth: 22 mm
- power: +12 V 8 mA, −12 V 0 mA, +5 V ? mA
- status: current
- functions: End-of-Cycle / End-of-Rise Output

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| EOR 1 | gate, trigger | end of rise | 0 to 5 V | unipolar | Quadrax channel 1 | 1245 |
| EOF 1 | gate, trigger | end of fall | 0 to 5 V | unipolar | Quadrax channel 1 | 1245 |
| EOR 2 | gate, trigger | end of rise | 0 to 5 V | unipolar | Quadrax channel 2 | 1245 |
| EOF 2 | gate, trigger | end of fall | 0 to 5 V | unipolar | Quadrax channel 2 | 1245 |
| EOR 3 | gate, trigger | end of rise | 0 to 5 V | unipolar | Quadrax channel 3 | 1245 |
| EOF 3 | gate, trigger | end of fall | 0 to 5 V | unipolar | Quadrax channel 3 | 1245 |
| EOR 4 | gate, trigger | end of rise | 0 to 5 V | unipolar | Quadrax channel 4 | 1245 |
| EOF 4 | gate, trigger | end of fall | 0 to 5 V | unipolar | Quadrax channel 4 | 1245 |

## Modes

- AD [1245]
- AHR [1245]
- CYCLE [1245]
- BURST [1245]
- LFO [1245]
- ALTERNATE LFO [1245]

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 4 HP | — | 1245 |
| module | depth | 22 mm | — | 1245 |
| module | +12V current | 8 mA | — | 1245 |
| module | -12V current | 0 mA | — | 1245 |
| EOR/EOF outputs | high level | 5 V | — | 1245 |
| EOR/EOF outputs | low level | 0 V | — | 1245 |

## Behavior

- EOR: when AD: attack reaches maximum → goes high (AD) [1245]
- EOR: when AD: decay phase completes → goes low (AD) [1245]
- EOF: when AD: attack reaches maximum → goes low (0V) (AD) [1245]
- EOF: when AD: decay cycle completes → goes high (AD) [1245]
- EOR: when AHR: attack reaches maximum → goes high (AHR) [1245]
- EOR: when AHR: release phase ends → goes low (AHR) [1245]
- EOF: when AHR: release phase starts → goes low (0V) (AHR) [1245]
- EOF: when AHR: release cycle completes → goes high (AHR) [1245]
- EOR: when CYCLE: attack half reaches maximum → goes high (CYCLE) [1245]
- EOR: when CYCLE: decay phase completes → goes low (0V) (CYCLE) [1245]
- EOF: when CYCLE: attack half reaches maximum → goes low (0V) (CYCLE) [1245]
- EOF: when CYCLE: decay phase completes → goes high (CYCLE) [1245]
- EOR: when BURST: each pulse begins → high for first half (BURST) [1245]
- EOF: when BURST: during burst length → stays 0V (BURST) [1245]
- EOF: when BURST: overall burst ends → high until next burst (BURST) [1245]
- EOR: when standard LFO: half-way through cycle → goes high (LFO) [1245]
- EOR: when standard LFO: cycle resets → drops to 0V (LFO) [1245]
- EOF: when standard LFO: first half → high (LFO) [1245]
- EOF: when standard LFO: second half → low (0V) (LFO) [1245]
- EOR: when alternate LFO: voltage moving negative → high (ALTERNATE LFO) [1245]
- EOF: when alternate LFO: voltage moving positive → high (ALTERNATE LFO) [1245]
- Qx: when Quadrax absent → does not function [1245]
- Qx: when used without Quadrax → requires Quadrax [1246]
- I2C cable: when connecting or disconnecting → power down first [1245]

## Sources

- [1245] intellijel Qx manual (manual): https://intellijel.com/downloads/manuals/quadrax_manual_1.4.5_2026.09.11.pdf
- [1246] intellijel Qx product page (product_page): https://intellijel.com/shop/eurorack/qx/

Full record as JSON: https://eurorackref.com/intellijel/qx.json