# A-198 (Doepfer)

Canonical page: https://eurorackref.com/doepfer/a-198/

- id: `doepfer/a-198`
- width: 8 HP; depth: 40 mm
- power: +12 V 40 mA, −12 V 20 mA, +5 V ? mA
- status: current
- functions: Manual Controller

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| Contr. Board | — | sensor manual connector | unknown | unknown | — | 1860 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| CV (Position) | cv, pitch | position control voltage | not stated | unknown | position sensor, S&H circuit | 1860 |
| Gate (Position) | gate | position gate | not stated | unknown | position sensor | 1860 |
| CV (Pressure) | cv | pressure control voltage | not stated | unknown | pressure sensor | 1860 |
| Gate (Pressure) | gate | pressure gate | not stated | unknown | pressure sensor | 1860 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| Scale (Position) | knob | position CV scale | 0 to 10 | CV (Position) | 1860 |
| Hold | switch | hold function | — | CV (Position), Gate (Position), S&H circuit | 1860 |
| Thres | knob | pressure gate threshold | 0 to 10 | Gate (Pressure) | 1860 |
| Scale (Pressure) | knob | pressure CV scale | 0 to 10 | CV (Pressure) | 1860 |

## Modes

- Hold Off (Hold = Off) [1860]
- Hold On (Hold = On) [1860]

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 8 HP | — | 1861 |
| module | depth | 40 mm | — | 1861 |
| module | +12V current | 40 mA | module + manual | 1861 |
| module | -12V current | 20 mA | module + manual | 1861 |
| position sensor | length | 50 cm | — | 1860 |
| manual | length | 600 mm | — | 1861 |
| manual | weight | 1 kg | — | 1861 |

## Behavior

- CV (Position): when finger removed, Hold Off → drops to 0V (Hold Off) [1860]
- Gate (Position): when finger removed, Hold Off → turns low (Hold Off) [1860]
- Gate (Position): when finger touches, Hold Off → high (Hold Off) [1860]
- CV (Position): when finger removed, Hold On → last CV held (Hold On) [1860]
- Gate (Position): when Hold On → permanently high (Hold On) [1860]
- Gate (Position): when Hold active → no gate generated (Hold On) [1861]
- CV (Position): when held for long → drifts slowly (Hold On) [1861]
- Gate (Pressure): when pressure CV exceeds threshold → turns high [1860]
- Contr. Board: when USB device connected → both devices destroyed [1860]

## Sources

- [1860] Doepfer A-198 manual (manual): https://doepfer.de/a100_man/A198_man.pdf
- [1861] Doepfer A-198 product page (product_page): https://doepfer.de/a198.htm