# A-178 (Doepfer)

Canonical page: https://eurorackref.com/doepfer/a-178/

- id: `doepfer/a-178`
- width: 8 HP; depth: 40 mm
- power: +12 V 60 mA, −12 V 20 mA, +5 V ? mA
- status: current
- functions: Manual Controller

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| Antenna | — | antenna input | not stated | unknown | — | 1848 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| CV Out 1 | cv | theremin control voltage | -10 to 10 V | bipolar | Theremin | 1848 |
| CV Out 2 | cv | theremin control voltage | -10 to 10 V | bipolar | Theremin | 1848 |
| Gate Out | gate | gate above threshold | 0 to 10 V | unipolar | Gate function | 1848 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| Offset | knob | null point adjust | 0 to 10 | Theremin, CV Out 1, CV Out 2 | 1848 |
| Threshold | knob | gate threshold | 0 to 10 | Gate function, Gate Out | 1848 |
| Frequency Offset | other | coarse offset trim | — | Theremin | 1848 |

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 8 HP | — | 1849 |
| module | depth | 40 mm | — | 1849 |
| module | +12V current | 60 mA | — | 1849 |
| module | -12V current | 20 mA | — | 1849 |
| Antenna | distance range | 30 to 40 cm | — | 1849 |
| Offset | null point hand distance | ≥ 30 cm | — | 1848 |
| module | width | 40.3 mm | — | 1849 |

## Behavior

- CV Out: when hand approaches antenna → voltage rises (factory) [1848]
- CV Out: when trim set to falling edge → voltage falls approaching antenna [1848]
- Gate Out: when CV above Threshold → gate high [1848]
- CV Out: when hand beyond about 30 cm → 0 V after Offset adjust [1848]
- Offset: when each use → adjustment check needed [1848]
- Offset: when other antenna, null unreachable → use internal trim [1848]
- Antenna: when cable or other element → module will not work [1849]
- two A-178: when closer than 40-50 cm → antennas affect each other [1849]
- module: when housing not grounded → theremin circuit malfunctions [1849]

## Sources

- [1848] Doepfer A-178 manual (manual): https://doepfer.de/a100_man/A178_man.pdf
- [1849] Doepfer A-178 product page (product_page): https://doepfer.de/a178.htm

Full record as JSON: https://eurorackref.com/doepfer/a-178.json