# A-166 (Doepfer)

Canonical page: https://eurorackref.com/doepfer/a-166/

- id: `doepfer/a-166`
- width: 8 HP; depth: 50 mm
- power: +12 V 40 mA, −12 V 20 mA, +5 V ? mA
- status: current
- functions: Logic Gates

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| Input 1 (1) | gate, clock, trigger | logic input 1 | not stated | unknown | — | 1846 |
| Input 2 (1) | gate, clock, trigger | logic input 2 | not stated | unknown | Input 1 (1) | 1846 |
| Input 3 (1) | gate, clock, trigger | logic input 3 | not stated | unknown | Input 2 (1) | 1846 |
| Input 1 (2) | gate, clock, trigger | logic input 1 | not stated | unknown | — | 1846 |
| Input 2 (2) | gate, clock, trigger | logic input 2 | not stated | unknown | Input 1 (2) | 1846 |
| Input 3 (2) | gate, clock, trigger | logic input 3 | not stated | unknown | Input 2 (2) | 1846 |
| Input (1) | gate | inverter input | not stated | unknown | — | 1846 |
| Input (2) | gate | inverter input | not stated | unknown | — | 1846 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| AND (1) | gate | AND function output | 0 to 12 V | unknown | Logic Unit 1 | 1846 |
| OR (1) | gate | OR function output | 0 to 12 V | unknown | Logic Unit 1 | 1846 |
| XOR (1) | gate | XOR function output | 0 to 12 V | unknown | Logic Unit 1 | 1846 |
| AND (2) | gate | AND function output | 0 to 12 V | unknown | Logic Unit 2 | 1846 |
| OR (2) | gate | OR function output | 0 to 12 V | unknown | Logic Unit 2 | 1846 |
| XOR (2) | gate | XOR function output | 0 to 12 V | unknown | Logic Unit 2 | 1846 |
| INV (1) | gate | inverter output | 0 to 12 V | unknown | Inverter 1 | 1846 |
| INV (2) | gate | inverter output | 0 to 12 V | unknown | Inverter 2 | 1846 |

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 8 HP | — | 1847 |
| module | depth | 50 mm | — | 1847 |
| module | +12V current | 40 mA | — | 1847 |
| module | -12V current | 20 mA | — | 1847 |
| inputs | low threshold | 1 V | below = logical 0 | 1846 |
| inputs | high threshold | 2 V | above = logical 1 | 1846 |
| outputs | high level | 12 V | at least +10V | 1846 |
| outputs | low level | 0 V | below +1V | 1846 |

## Behavior

- Input 2: when unpatched → connected to Input 1 [1846]
- Input 3: when unpatched → connected to Input 2 [1846]
- AND: when all inputs high → high [1846]
- OR: when any input high → high [1846]
- XOR: when some but not all high → high [1846]
- XOR: when all three high → low [1846]
- INV output: when inverter input low → high [1846]
- inputs: when below about +1V → logical 0 [1846]
- inputs: when above about +2V → logical 1 [1846]

## Sources

- [1846] Doepfer A-166 manual (manual): https://doepfer.de/a100_man/a166_man.pdf
- [1847] Doepfer A-166 product page (product_page): https://doepfer.de/a166.htm

Full record as JSON: https://eurorackref.com/doepfer/a-166.json