# A-160-2 (Doepfer)

Canonical page: https://eurorackref.com/doepfer/a-160-2/

- id: `doepfer/a-160-2`
- width: 4 HP; depth: 35 mm
- power: +12 V 50 mA, −12 V 0 mA, +5 V ? mA
- status: current
- functions: Clock Divider / Multiplier

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| Clock In | clock, trigger, gate | clock input | not stated | unknown | — | 1842 |
| Reset In | gate, trigger | reset input | not stated | unknown | — | 1842 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| Div 1 | clock, gate, trigger | divided clock output 1 | 0 to 10 V | unknown | Clock Divider | 1842 |
| Div 2 | clock, gate, trigger | divided clock output 2 | 0 to 10 V | unknown | Clock Divider | 1842 |
| Div 3 | clock, gate, trigger | divided clock output 3 | 0 to 10 V | unknown | Clock Divider | 1842 |
| Div 4 | clock, gate, trigger | divided clock output 4 | 0 to 10 V | unknown | Clock Divider | 1842 |
| Div 5 | clock, gate, trigger | divided clock output 5 | 0 to 10 V | unknown | Clock Divider | 1842 |
| Div 6 | clock, gate, trigger | divided clock output 6 | 0 to 10 V | unknown | Clock Divider | 1842 |
| Div 7 | clock, gate, trigger | divided clock output 7 | 0 to 10 V | unknown | Clock Divider | 1842 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| Divider Set switch | switch | dividing factor set | — | Clock Divider, Div 1, Div 2, Div 3, Div 4, Div 5, Div 6, Div 7 | 1842 |
| Output mode switch | switch | gate/trigger output mode | — | Div 1, Div 2, Div 3, Div 4, Div 5, Div 6, Div 7 | 1842 |
| Clock edge jumper | jumper | clock edge type | — | Clock Divider | 1842 |
| Reset trigger jumper | jumper | reset level/edge | — | Reset In | 1842 |
| Reset polarity jumper | jumper | reset polarity | — | Reset In | 1842 |
| Output polarity jumper | jumper | output polarity | — | Div 1, Div 2, Div 3, Div 4, Div 5, Div 6, Div 7 | 1842 |

## Modes

- power of two (Divider Set switch = power of two) [1842]
- prime numbers (Divider Set switch = prime numbers) [1842]
- integer (Divider Set switch = integer) [1842]
- Gate (Output mode switch = Gate) [1842]
- Trigger (Output mode switch = Trigger) [1842]
- Cst (Output mode switch = Cst) [1842]

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 4 HP | — | 1842 |
| module | depth | 35 mm | — | 1842 |
| module | +12V current | 50 mA | — | 1842 |
| module | -12V current | 0 mA | — | 1842 |
| Clock Divider | division ratio | 2 to 128 ratio | power of two | 1842 |
| Clock Divider | division ratio | 2 to 17 ratio | prime numbers | 1842 |
| Clock Divider | division ratio | 2 to 8 ratio | integer | 1842 |
| Reset In | high threshold | 2.5 V | positive reset jumper | 1842 |
| Reset In | low threshold | 1 V | negative reset jumper | 1842 |
| outputs | high level | 10 V | about | 1842 |
| outputs | low level | 0 V | — | 1842 |

## Behavior

- all outputs: when reset signal sensed → set to mode-dependent levels [1842]
- outputs: when Trigger mode → AND-wired with clock (Trigger) [1842]
- output pulsewidth: when Trigger mode → follows clock pulsewidth (Trigger) [1842]
- outputs: when Gate mode → act as binary dividers (Gate) [1842]
- outputs: when Cst position selected → no function yet (Cst) [1842]
- outputs: when output polarity jumper negative → all seven inverted [1842]
- Reset: when positive, level jumper → high level >2.5V resets [1842]
- Reset: when negative, level jumper → low level <1V resets [1842]

## Sources

- [1842] Doepfer A-160-2 product page (product_page): https://doepfer.de/a1602.htm

Full record as JSON: https://eurorackref.com/doepfer/a-160-2.json