# A-149-1 (Doepfer)

Canonical page: https://eurorackref.com/doepfer/a-149-1/

- id: `doepfer/a-149-1`
- width: 12 HP; depth: 60 mm
- power: +12 V 40 mA, −12 V 10 mA, +5 V ? mA
- status: current
- functions: Random / Sample & Hold CV

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| CV N In | cv | CV input for N | not stated | unknown | — | 1836 |
| Clk In (Quantized) | clock, gate | clock for Quantized RCV | unknown | unknown | — | 1836 |
| CV D In | cv | CV input for distribution | not stated | unknown | — | 1836 |
| Clk In (Stored) | clock, gate | clock for Stored RCV | unknown | unknown | — | 1836 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| n+1 | cv, pitch | N+1 states output | 0 to 5 V | unipolar | Quantized Random Voltages | 1836 |
| 2^n | cv, pitch | 2^N states output | 0 to 5.25 V | unipolar | Quantized Random Voltages | 1836 |
| Even Distribution Out | cv | equal probability output | 0 to 5.3 V | unipolar | Stored Random Voltages | 1836 |
| Distribution Out | cv | adjustable distribution output | 0 to 5.3 V | unipolar | Stored Random Voltages | 1836 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| Man N | knob | manual control of N | 1 to 6 N | Quantized Random Voltages, n+1, 2^n | 1836 |
| CV N | knob | attenuator for CVN | — | CV N In | 1836 |
| Man D | knob | distribution D | — | Stored Random Voltages, Distribution Out | 1836 |
| CV D | knob | attenuator for CVD | — | CV D In | 1836 |

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 12 HP | — | 1837 |
| module | depth | 60 mm | — | 1837 |
| module | +12V current | 40 mA | — | 1837 |
| module | -12V current | 10 mA | — | 1837 |
| Quantized Random Voltages | N | 1 to 6 integer | — | 1836 |
| n+1 | states | 2 to 7 states | — | 1836 |
| 2^n | states | 2 to 64 states | — | 1836 |
| n+1 | voltage step | 1 V | factory trim | 1836 |
| 2^n | voltage step | 0.0833 V | 1/12 V, factory trim | 1836 |
| n+1 | output range | 0 to 5 V | — | 1836 |
| 2^n | output range | 0 to 5.25 V | — | 1836 |
| Stored Random Voltages | states | 256 states | — | 1836 |
| Stored Random Voltages | voltage step | 0.0208 V | about 1/48 V | 1836 |
| Stored Random Voltages | output range | 0 to 5.3 V | — | 1836 |
| Clk In | max clock frequency | 2000 Hz | — | 1837 |

## Behavior

- Clk In (Quantized): when rising edge → new n+1, 2^n values [1836]
- Clk In (Stored): when rising edge → new stored random values [1836]
- N: when manual plus CV → summed [1836]
- D: when manual plus CV → summed [1836]
- Man D: when fully counterclockwise → mostly low voltages [1836]
- Man D: when turned right/positive CV → higher voltages more probable [1836]
- Even Distribution Out: when always → all states equally likely [1836]
- 2^n: when N increases → states grow exponentially [1837]
- n+1: when N increases → states grow linearly [1837]

## Sources

- [1836] Doepfer A-149-1 manual (manual): https://doepfer.de/a100_man/a1491_man.pdf
- [1837] Doepfer A-149-1 product page (product_page): https://doepfer.de/a1491.htm

Full record as JSON: https://eurorackref.com/doepfer/a-149-1.json