# A-148 (Doepfer)

Canonical page: https://eurorackref.com/doepfer/a-148/

- id: `doepfer/a-148`
- width: 4 HP; depth: 30 mm
- power: +12 V 20 mA, −12 V 20 mA, +5 V ? mA
- status: current
- functions: Random / Sample & Hold CV

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| Trig. In 1 | trigger, gate | sampling trigger | unknown | unknown | — | 1834 |
| Smp. In 1 | cv, audio | signal to be sampled | -12 to 12 V | bipolar | — | 1834 |
| Trig. In 2 | trigger, gate | sampling trigger | unknown | unknown | — | 1834 |
| Smp. In 2 | cv, audio | signal to be sampled | -12 to 12 V | bipolar | — | 1834 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| S&H Out 1 | cv | sampled and held voltage | not stated | unknown | S&H 1 | 1834 |
| S&H Out 2 | cv | sampled and held voltage | not stated | unknown | S&H 2 | 1834 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| JP2 | jumper | S&H / T&H select | — | S&H 1, S&H 2 | 1834 |
| JP3 | jumper | S&H / T&H select | — | S&H 1, S&H 2 | 1834 |

## Modes

- S&H (JP2 = S&H) [1834]
- T&H (JP2 = T&H) [1834]

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 4 HP | — | 1835 |
| module | depth | 30 mm | — | 1835 |
| module | +12V current | 20 mA | — | 1835 |
| module | -12V current | 20 mA | — | 1835 |
| Smp. In | input range | -12 to 12 V | version from August 2005 | 1834 |
| Smp. In | input range | -8 to 8 V | version before August 2005 | 1834 |
| S&H Out | hold drift | 30 mV/min | typical, hold phase | 1835 |

## Behavior

- Trig. In: when leading edge → sample taken (S&H) [1834]
- S&H Out: when trigger high → follows input (T&H) [1834]
- S&H Out: when trigger turns low → last voltage stored (T&H) [1834]
- S&H 1: when factory setting → S&H mode [1834]
- S&H 2: when factory setting → T&H mode [1834]
- Smp. In: when beyond ±8V, old version → S&H stops working [1834]
- Smp. In: when within ±12V → no damage [1834]
- + LED: when positive held voltage → lights [1834]
- - LED: when negative held voltage → lights [1834]
- S&H Out: when long hold → voltage drifts [1835]

## Sources

- [1834] Doepfer A-148 manual (manual): https://doepfer.de/a100_man/A148_man.pdf
- [1835] Doepfer A-148 product page (product_page): https://doepfer.de/a148.htm

Full record as JSON: https://eurorackref.com/doepfer/a-148.json