# 182 Analog Sequencer (Behringer)

Canonical page: https://eurorackref.com/behringer/182/

- id: `behringer/182`
- width: unknown HP; depth: unknown mm
- power: +12 V ? mA, −12 V ? mA, +5 V ? mA
- status: current
- functions: Step Sequencer, Slew Limiter

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| TEMPO CV IN | cv | tempo clock CV | not stated | not stated | — | 764 |
| TRIG IN | trigger | trigger input | not stated | not stated | — | 764 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| CV OUT-1 | cv | CH-1 column CV | not stated | not stated | CH-1 column, DELAY | 764 |
| CV OUT-2 | cv | CH-2 column CV | not stated | not stated | CH-2 column | 764 |
| GATE OUT | gate | per-step gate | not stated | not stated | tempo clock | 764 |
| TRIG OUT | trigger | end-step trigger | not stated | not stated | tempo clock | 764 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| CH-1/CH-2 SEQUENCER COLUMNS | knob | per-step CV | — | CH-1 column, CH-2 column, CV OUT-1, CV OUT-2 | 764 |
| TEMPO | knob | step speed | — | tempo clock | 764 |
| DELAY | knob | glide to next step | 0 to 10 s | CV OUT-1 | 764 |
| GATE TIME | knob | GATE OUT duty cycle | 10 to 90 % | GATE OUT | 764 |
| STEP NUMBER | knob | sequence length | — | CH-1 column, CH-2 column | 764 |
| STEP (REPEAT/SINGLE) | switch | trigger response | — | tempo clock, TRIG IN | 764 |
| START/STOP | button | start or stop sequence | — | tempo clock | 764 |
| PARALLEL/SERIES | switch | column chaining | — | CH-1 column, CH-2 column | 764 |

## Modes

- PARALLEL (PARALLEL/SERIES = PARALLEL) [764]
- SERIES (PARALLEL/SERIES = SERIES) [764]
- REPEAT (STEP (REPEAT/SINGLE) = REPEAT) [764]
- STEP (STEP (REPEAT/SINGLE) = STEP) [764]
- SINGLE (STEP (REPEAT/SINGLE) = SINGLE) [764]

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| DELAY | transition time | 0 to 10 s | — | 764 |
| GATE TIME | duty cycle | 10 to 90 % | — | 764 |
| sequencer | steps | ≤ 8 steps | PARALLEL | 764 |
| sequencer | steps | 8 to 16 steps | SERIES | 764 |
| CH-1/CH-2 SEQUENCER COLUMNS | knob count | 16 knobs | — | 764 |

## Behavior

- DELAY: when CV OUT-2 → unaffected by DELAY [764]
- DELAY: when PARALLEL or SERIES → applies to CV OUT-1 [764]
- STEP NUMBER: when SERIES mode → affects only CH-2 (SERIES) [764]
- STEP NUMBER: when PARALLEL mode → affects both columns (PARALLEL) [764]
- sequence: when REPEAT, end reached → repeats (REPEAT) [764]
- sequence: when SINGLE, one cycle done → stops (SINGLE) [764]
- sequence: when STEP, TRIG IN trigger → advances one step (STEP) [764]
- sequence: when SERIES mode → CH-1 first, then CH-2 (SERIES) [764]
- TRIG OUT: when end step reached → trigger generated [764]

## Sources

- [764] Behringer 182 Analog Sequencer manual (mirror of official documentation via device.report) (manual): https://device.report/manual/14146859

Full record as JSON: https://eurorackref.com/behringer/182.json