# Tape Stop (2hp)

Canonical page: https://eurorackref.com/2hp/tape-stop/

- id: `2hp/tape-stop`
- width: 2 HP; depth: 46 mm
- power: +12 V 101 mA, −12 V 7 mA, +5 V 0 mA
- status: current
- functions: Tempo / Clock Sync

## Inputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| IN | audio | audio input | -5 to 5 V | unknown | not stated | 1426 |
| CLOCK | clock | external clock sync | not stated | unknown | not stated | 1426 |
| TRIG | gate | trig gate input | not stated | unknown | not stated | 1426 |
| LAG | cv | lag CV input | -5 to 5 V | bipolar | not stated | 1426 |

## Outputs

| Jack | Signals | Function | Voltage | Polarity | Normalled from / comes from | Source |
|---|---|---|---|---|---|---|
| OUT | audio | audio output | -5 to 5 V | unknown | tape stop | 1426 |

## Controls

| Control | Type | Function | Range | Affects | Source |
|---|---|---|---|---|---|
| TRIG | button | begin tape stop | — | tape stop | 1426 |
| LAG | knob | tape stop length | 0 to 4 s | tape stop | 1426 |
| Trig Toggle | switch | trig behavior | — | TRIG | 1426 |

## Modes

- Momentary (Trig Toggle = down) [1426]
- Latching (Trig Toggle = up) [1426]
- 50/50 Mode [1426]
- clock-synced [1426]

## Specs

| Subject | Quantity | Value | Condition | Source |
|---|---|---|---|---|
| module | width | 2 HP | — | 1426 |
| module | depth | 46 mm | — | 1426 |
| module | +12V current | 101 mA | — | 1426 |
| module | -12V current | 7 mA | — | 1426 |
| module | +5V current | 0 mA | — | 1426 |
| LAG | tape stop length | 0 to 4 s | — | 1426 |
| LAG | tape stop length | 0 to 16 bars | clock-synced | 1426 |
| tape stop | dry wet mix | 50 % | 50/50 Mode | 1426 |
| IN | input range | 10 Vpp | — | 1426 |
| OUT | output range | 10 Vpp | — | 1426 |

## Behavior

- TRIG: when pressed → tape stop begins [1426]
- TRIG: when button released → tape stop ends (Momentary) [1426]
- TRIG: when pressed second time → tape stop ends (Latching) [1426]
- LAG: when clock synced → length in note divisions (clock-synced) [1426]
- LAG: when knob fully left → instant stop [1426]
- module: when Trig held at boot → dry/wet set to 50% [1426]
- TRIG LED: when external clock patched → blinks at clock rate [1426]
- tape stop: when Trig hit again → audio resumes seamlessly (Latching) [1427]

## Sources

- [1426] 2hp Tape Stop manual (manual): https://www.twohp.com/s/2hp_Tape_Stop.pdf
- [1427] 2hp Tape Stop product page (product_page): https://www.twohp.com/modules/p/tape-stop

Full record as JSON: https://eurorackref.com/2hp/tape-stop.json